ArticleBMC medical informatics and decision making2022
Electronic prescribing systems as tools to improve patient care: a learning health systems approach to increase guideline concordant prescribing for venous thromboembolism prevention.
Article in BMC medical informatics and decision making, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 8 citations in OpenAlex.
- A clinical decision support tool for improving venous thromboembolism risk assessment and thromboprophylaxis prescribing compliance within an electronic medication management system: a retrospective observational study.International journal of clinical pharmacy · 2025Observational
- Clinical decision support systems for maternity care: a systematic review and meta-analysis.EClinicalMedicine · 2024Article
- Do Decision Support Tools Decrease the Prevalence of Hospital-Acquired Venous Thromboembolisms When Compared to Clinical Judgement? A Single-Center Pre-Post Study.Journal of clinical medicine · 2024Article
- Implementation of early prophylaxis for deep-vein thrombosis in intracerebral hemorrhage patients: an observational study from the Chinese Stroke Center Alliance.Thrombosis journal · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundVenous thromboembolism (VTE) causes significant mortality and morbidity in hospitalised patients. Risk factors for VTE are well known and there are validated risk assessment tools to support the use of prophylactic therapies. In England, reporting the percentage of patients with a completed VTE risk assessment is mandated, but this does not include whether that risk assessment resulted in appropriate prescribing. Full guideline compliance, defined as an assessment which led to an appropriate action-here prescribing prophylactic low molecular weight heparin where indicated, is rarely reported. Education, audit and feedback enhance guideline compliance but electronic prescribing systems (EPS) can mandate guideline-compliant actions. We hypothesised that a systems-based EPS intervention (prescribing rules which mandate approval or rejection of a proposed prescription of prophylactic low molecular weight heparin based on the mandated VTE assessment) would increase full VTE guideline compliance more than interventions which focused on targeting individual prescribers.
methodsAll admitted patients within University Hospitals Birmingham NHS Foundation Trust were included for analysis between 2011 and 2020. The proportion of patients who received a fully compliant risk assessment and action was assessed over time. Interventions included teaching sessions and face-to-face feedback based on measured performance (an approach targeting individual prescribers) and mandatory risk assessment and prescribing rules into an EPS (a systems approach).
resultsData from all 235,005 admissions and all 5503 prescribers were included in the analysis. Risk assessments were completed in > 90-95% of all patients at all times, but full guideline compliance was lower (70% at the start of this study). Face-to-face feedback improved full VTE guideline compliance from 70 to 77% (p ≤ 0.001). Changes to the EPS to mandate assessment with prescribing rules increased full VTE compliance to 95% (p ≤ 0.001). Further amendments to the EPS system to reduce erroneous VTE assessments slightly reduced full compliance to 92% (p < 0.001), but this was then maintained including during changes to the low molecular weight heparin used for VTE prophylaxis. DISCUSSION: An EPS-systems approach was more effective in improving sustained guideline-compliant VTE prevention over time. Non-compliance remained at 8-5% despite this mandated system. Further research is needed to assess the potential reasons for this.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.