3D printed anthropomorphic left ventricular myocardial phantom for nuclear medicine imaging applications.

Janos Kiss, Laszlo Balkay, Kornel Kukuts, Marton Miko, Attila Forgacs, Gyorgy Trencsenyi, Aron K Krizsan

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Janos KissDivision of Radiology and Imaging Science, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98., Debrecen, 4032, Hungary. kiss.janos31@med.unideb.hu.ORCID http://orcid.org/0000-0002-4379-8409
Laszlo BalkayDivision of Nuclear Medicine and Translational Imaging, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98., Debrecen, 4032, Hungary.
Kornel KukutsScanoMed Nuclear Medicine Centers, Nagyerdei krt. 98., Debrecen, 4032, Hungary.
Marton MikoDivision of Nuclear Medicine and Translational Imaging, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98., Debrecen, 4032, Hungary.
Attila ForgacsScanoMed Nuclear Medicine Centers, Nagyerdei krt. 98., Debrecen, 4032, Hungary.
Gyorgy TrencsenyiDivision of Nuclear Medicine and Translational Imaging, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98., Debrecen, 4032, Hungary.
Aron K KrizsanScanoMed Nuclear Medicine Centers, Nagyerdei krt. 98., Debrecen, 4032, Hungary.
University of Debrecen · HUEgis Pharmaceuticals (Hungary) · HU

Funding

Innovációs és Technológiai Minisztérium Thematic Excellence Programme (TKP2020-NKA-04)
6 · The paper itself

Abstract

backgroundAnthropomorphic torso phantoms, including a cardiac insert, are frequently used to investigate the imaging performance of SPECT and PET systems. These phantom solutions are generally featuring a simple anatomical representation of the heart. 3D printing technology paves the way to create cardiac phantoms with more complex volume definition. This study aimed to describe how a fillable left ventricular myocardium (LVm) phantom can be manufactured using geometry extracted from a patient image.

methodsThe LVm of a healthy subject was segmented from

resultsPhantoms were easy to fill without any air-bubbles or leakage, were found to be reproducible and fully compatible with the torso phantom. Seventeen segments polar map analysis of the "in air" measurements revealed that a significant deficit in the distribution appeared where it was expected. 59% of polar map segments had less than 5% deviation for the "in torso" and "in air" measurement comparison. Excluding the deficit area, neither comparison had more than a 12.4% deviation. All the three polar maps showed similar apex and apical region values for all configurations.

conclusionsFillable anthropomorphic 3D printed phantom of LVm can be produced with high precision and reproducibility. The 3D printed LVm phantoms were found to be suitable for SPECT image quality tests during different imaging scenarios. The flexibility of the 3D printing process presented in this study provides scalable and anthropomorphic image quality phantoms in nuclear cardiology imaging.

Indexed as

3D printingCardiacPhantomSPECTTechnetium-99m