Evidence map›Paper›PMID 35502038›Full record

ArticleIndian journal of ophthalmology2022

Histopathological analysis of residual lens cells in capsular opacities after cataract surgery using objective software.

Christina Mastromonaco, Matthew Balazsi, Jacqueline Coblentz, Ana Beatriz Toledo Dias, Pablo Zoroquiain, Miguel N Burnier

Open access · diamondAbstract read
In one paragraph

Article in Indian journal of ophthalmology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Christina MastromonacoDepartment of Pathology and Ophthalmology, The MUHC-McGill University Ocular Pathology Laboratory, Montreal, Quebec, Canada.
Matthew BalazsiMedical Parachute, Montreal, Quebec, Canada.
Jacqueline CoblentzDepartment of Pathology and Ophthalmology, The MUHC-McGill University Ocular Pathology Laboratory, Montreal, Quebec, Canada.
Ana Beatriz Toledo DiasDepartment of Pathology and Ophthalmology, The MUHC-McGill University Ocular Pathology Laboratory, Montreal, Quebec, Canada.
Pablo ZoroquiainDepartment of Pathology and Ophthalmology, The MUHC-McGill University Ocular Pathology Laboratory, Montreal, Quebec, Canada.
Miguel N BurnierDepartment of Pathology and Ophthalmology, The MUHC-McGill University Ocular Pathology Laboratory, Montreal, Quebec, Canada.
McGill University · CACreative Commons · USParachute · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Remnant lens epithelial cells (LECs) within the capsular bag (CB) undergo epithelial-to-mesenchymal transition (EMT) and acquire a myofibroblast phenotype, depositing extracellular matrix (ECM) components, leading to posterior capsular opacification (PCO). This study histopathologically analyzes the LEC-to-myofibroblast transition and de novo ECM component deposition (i.e., smooth muscle actin (SMA) and fibronectin (FN) expression) and determines the intraocular lens (IOL) and patient factors associated with these changes. Methods: In total, 190 CBs with IOLs were removed from donor eyes. Digital images were obtained, and PCO was graded using published software (ADOS, Medical Parachute). Automated immunohistochemistry was performed using anti-SMA to detect EMT and anti-FN to document ECM remodeling. Slides were digitized and analyzed using the Positive Pixel Count v9 algorithm. Linear regression and Poisson regression were performed (P < 0.05). Results: SMA positive expression decreased as the time of IOL implantation increased (P < 0.0001). Positivity of SMA and FN demonstrated a positive correlation (P = 0.0002). Controlling for confounding factors in Poisson regression, hydrophobic and hydrophilic materials showed higher FN and SMA expression when compared to silicone material lenses (FN; P = 0.018; P < 0.0001, SMA; P = 0.001; P = 0.003, respectively). The square optic design had 29% higher SMA positivity compared to the opti-edge design (P = 0.042). One-piece haptic lenses had higher SMA expression compared to three-piece haptic (P = 0.042). A higher risk of expression of SMA and FN was seen in patients with a history of smoking, hypertension, and glaucoma (P < 0.05). Conclusion: This study demonstrated that SMA and FN expression is different according to IOL design and patient factors, thus indicating that LEC changes depend on lens biocompatibility. Therefore, by analyzing the histopathological composition of PCO by using LECs, further insight into the characteristics of IOLs that are important for biocompatibility can be ascertained.

Indexed as

Capsule OpacificationLens, CrystallineLenses, IntraocularEpithelial CellsHumansSoftwareCapsular opacificationimmunohistochemistryintraocular lensobjective softwarepost-mortem eyes

Identifiers

PMID35502038
PMCPMC9332936
OpenAlexW4225410138

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.