Evidence map›Paper›PMID 35501474›Full record

ArticleHypertension research : official journal of the Japanese Society of Hypertension2022

Validation of an ambulatory blood pressure monitoring device employing a novel method to detect atrial fibrillation.

Tomonori Watanabe, Naoko Tomitani, Nobuhiko Yasui, Kazuomi Kario

Abstract read
PubMed Publisher
In one paragraph

Article in Hypertension research : official journal of the Japanese Society of Hypertension, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Ambulatory blood pressure monitoring with atrial fibrillation detection algorithm: two birds with one stone.Hypertension research : official journal of the Japanese Society of Hypertension · 2024
    Article
  4. Digital hypertension towards to the anticipation medicine.Hypertension research : official journal of the Japanese Society of Hypertension · 2023
    Review
  5. Quality is not an act, it is a habit-Aristotle.Hypertension research : official journal of the Japanese Society of Hypertension · 2023
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Tomonori WatanabeDivision of Cardiovascular Medicine, Department of Internal Medicine, Jichi Medical University, Tochigi, Japan.
Naoko TomitaniDivision of Cardiovascular Medicine, Department of Internal Medicine, Jichi Medical University, Tochigi, Japan.
Nobuhiko YasuiA&D Co, Tokyo, Japan.
Kazuomi KarioDivision of Cardiovascular Medicine, Department of Internal Medicine, Jichi Medical University, Tochigi, Japan. kkario@jichi.ac.jp.
Jichi Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We evaluated the accuracy of a 24-hr ambulatory blood pressure monitoring (ABPM) device with a new irregular heartbeat (IHB) algorithm for detecting atrial fibrillation (AF) during each BP measurement. Ninety patients with a history of elevated BP and some type of arrhythmia (mean age 63.2 ± 10.3 years; 94% with hypertension; 81% with previously diagnosed AF) simultaneously underwent evaluation by 24-hr ABPM with the IHB algorithm and 24-hr Holter electrocardiography (ECG). Among the 3,347 valid readings, 843 readings were considered to indicate an IHB. Among these IHB readings, 195 readings were found to have an AF rhythm by 24-hr Holter ECG. The IHB algorithm showed 100% sensitivity and 79.4% specificity for accurately detecting AF rhythm. An IHB was detected in 12.1% of the measurements during normal rhythm, 48.8% of those during atrial premature complex, and 54.4% of those during ventricular premature complex. The percentage of IHBs detected during normal rhythm was higher in the daytime than at nighttime (16.3% vs. 4.5%, respectively), suggesting that daytime physical activity sometimes induces a false detection of IHBs. The optimal IHB parameters for suggesting potential AF were (1) an IHB burden defined as a percentage of IHB-positive readings in total valid BP measurements >22.5% (84.6% sensitivity, 85.1% specificity; AUC 0.906, p < 0.0001) and (2) 2.5 or more consecutive IHBs during 24-hr ABPM (84.6% sensitivity, 83.0% specificity; AUC 0.881, p < 0.0001). The novel 24-hr ABPM device with the IHB algorithm assessed herein could contribute to the future comprehensive management of hypertensive patients, with the main goal of preventing cerebrovascular events.

Indexed as

Atrial FibrillationHypertensionAgedBlood PressureBlood Pressure DeterminationBlood Pressure Monitoring, AmbulatoryHumansMiddle AgedAmbulatory blood pressure monitoringAtrial fibrillationIrregular heartbeat

Identifiers

PMID35501474
OpenAlexW4225265817

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.