Evidence map›Paper›PMID 35500010›Full record

ArticlePloS one2022

Skeletal muscle analysis of panoramic ultrasound is reliable across multiple raters.

Christopher J Cleary, Omid Nabavizadeh, Kaycie L Young, Ashley A Herda

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Christopher J ClearyDepartment of Health, Sport, and Exercise Sciences, University of Kansas Edwards Campus, Overland Park, Kansas, United States of America.ORCID 0000-0001-5664-8218
Omid NabavizadehDepartment of Geriatric Medicine, University of Colorado-Anschutz Medical Campus, Aurora, Colorado, United States of America.
Kaycie L YoungDepartment of Health, Sport, and Exercise Sciences, University of Kansas Edwards Campus, Overland Park, Kansas, United States of America.
Ashley A HerdaDepartment of Health, Sport, and Exercise Sciences, University of Kansas Edwards Campus, Overland Park, Kansas, United States of America.ORCID 0000-0002-6184-2055

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultrasound devices are common in muscle physiology laboratories due to their ease of use and validity to assess skeletal muscle characteristics. The current study assessed the reliability of ultrasound skeletal muscle image analysis across multiple raters with limited experience. Vastus lateralis (VL), rectus femoris (RF), and first dorsal interosseus (FDI) images were separately analyzed by three novice raters to determine muscle thickness (MT), cross-sectional area (CSA), and echo-intensity (EI). Separate analyses of variance (ANOVA) assessed statistical differences between and within raters. Intra-class correlation coefficients (ICC) between (inter-rater) and within (intra-rater) raters, the standard error of the measurement (SEM) and minimal difference needed to be considered real were calculated. Inter-rater reliability was high for the VL and RF (ICC: 0.984-0.999), while the FDI was lower (0.614-0.962). Further, intra-rater reliability was greater than 0.961 for each rater. SEM values calculated for inter-rater reliability expressed as a percentage of the mean ranged from 0.4-5.8% across variables. Similarly, SEM values for intra-rater reliability were between 0.8-5.8%, 0.6-3.6%, and 0.4-3.2% for Raters 1, 2 and 3, respectively. Despite this, significant differences (p<0.05) between raters were observed for RF MT and EI, VL CSA and EI, and FDI MT, suggesting that potentially more measurement trials or greater practice time may be necessary to reduce systematic error among multiple raters. Post-image acquisition processing is reliable among and within raters as determined through ICCs and SEMs. This study provided consistent results among three separate novice raters given the same training, a unique yet realistic setting in muscle physiology laboratories.

Indexed as

Back MusclesQuadriceps MuscleHumansObserver VariationReproducibility of ResultsUltrasonography

Identifiers

PMID35500010
PMCPMC9060372

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.