Evidence map›Paper›PMID 35498339›Full record

ArticleMicrosystems & nanoengineering2022

Nanoscale plasma-activated aerosol generation for in situ surface pathogen disinfection.

Nicholas S L Chew, Kiing S Wong, Wei S Chang, Chien W Ooi, Leslie Y Yeo, Ming K Tan

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nicholas S L ChewMechanical Engineering Discipline, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor Malaysia.
Kiing S WongMechanical Engineering Discipline, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor Malaysia.
Wei S ChangMechanical Engineering Discipline, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor Malaysia.
Chien W OoiChemical Engineering Discipline, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor Malaysia.
Leslie Y YeoMicro/Nanophysics Research Laboratory, RMIT University, Melbourne, VIC Australia.ORCID 0000-0002-5949-9729
Ming K TanMechanical Engineering Discipline, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor Malaysia.ORCID 0000-0002-1585-9358

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Plasma treatment constitutes an efficient method for chemical-free disinfection. A spray-based system for dispensing plasma-activated aerosols onto surfaces would facilitate disinfection of complex and/or hidden surfaces inaccessible to direct line-of-sight (for example, UV) methods. The complexity and size of current plasma generators (for example, plasma jet and cometary plasma systems)-which prohibit portable operation, together with the short plasma lifetimes, necessitate a miniaturized in situ technique in which a source can be simultaneously activated and administered on-demand onto surfaces. Here, we demonstrate this possibility by combining two nanoscale technologies for plasma and aerosol generation into an integrated device that is sufficiently small and lightweight. Plasma is generated on a carpet of zinc oxide nanorods comprising a nanoneedle ensemble, which when raised to a high electric potential, constitutes a massive point charge array with near-singular electric fields to effect atmospheric breakdown. The plasma is then used to activate water transported through an underlying capillary wick, that is subsequently aerosolized under MHz-order surface acoustic waves. We show that the system, besides being amenable to miniaturization and hence integration into a chipscale device, leads to a considerable improvement in plasma-activation over its macroscale cometary discharge predecessor, with up to 20% and 127% higher hydrogen peroxide and nitrite ion concentrations that are respectively generated in the plasma-activated aerosols. This, in turn, leads to a 67% reduction in the disinfection time to achieve 95% bacterial load reduction, therefore demonstrating the potential of the technology as an efficient portable platform for on-demand field-use surface disinfection.

Indexed as

MicrofluidicsNanostructures

Identifiers

PMID35498339
PMCPMC9008002

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.