Evidence map›Paper›PMID 35498338›Full record

ArticleMicrosystems & nanoengineering2022

Pico-washing: simultaneous liquid addition and removal for continuous-flow washing of microdroplets.

Michael J Siedlik, David Issadore

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Michael J SiedlikDepartment of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104 United States.
David IssadoreDepartment of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104 United States.

Funding

Center for Sub-Cellular GenomicsRM1HG010023 · NHGRI · UNIVERSITY OF PENNSYLVANIA · PI EBERWINE, JAMES H, KIM, JUNHYONG · 2018 to 2022
$11.0M
Nanomagnetic isolation and sensing for mobile HIV-1 self-testingR61AI147406 · NIAID · UNIVERSITY OF PENNSYLVANIA · PI ISSADORE, DAVID AARON · 2019 to 2021
$1.4M
Rapid unbiased isolation and in situ RNA analysis of circulating tumor cells using a magnetic micropore-based diagnostic chipR33CA206907 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ISSADORE, DAVID AARON · 2017 to 2019
$1.1M
A nanomagnetic platform technology to characterize traumatic brain injury using brain derived extracellular vesiclesR21MH118170 · NIMH · UNIVERSITY OF PENNSYLVANIA · PI ISSADORE, DAVID AARON · 2018 to 2019
$414k
Spatially-targeted heating of magnetic nanoparticlesR21EB023989 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI ISSADORE, DAVID AARON · 2018 to 2019
$411k
NCI NIH HHS R33 CA206907NHGRI NIH HHS RM1 HG010023NIAID NIH HHS R61 AI147406NIBIB NIH HHS R21 EB023989NIMH NIH HHS R21 MH118170
6 · The paper itself

Abstract

Droplet microfluidics is based on a toolbox of several established unit operations, including droplet generation, incubation, mixing, pico-injection, and sorting. In the last two decades, the development of droplet microfluidic systems, which incorporate these multiple unit operations into a workflow, has demonstrated unique capabilities in fields ranging from single-cell transcriptomic analyses to materials optimization. One unit operation that is sorely underdeveloped in droplet microfluidics is washing, exchange of the fluid in a droplet with a different fluid. Here, we demonstrate what we name the "pico-washer," a unit operation capable of simultaneously adding fluid to and removing fluid from droplets in flow while requiring only a small footprint on a microfluidic chip. We describe the fabrication strategy, device architecture, and process parameters required for stable operation of this technology, which is capable of operating with kHz droplet throughput. Furthermore, we provide an image processing workflow to characterize the washing process with microsecond and micrometer resolution. Finally, we demonstrate the potential for integrated droplet workflows by arranging two of these unit operations in series with a droplet generator, describe a design rule for stable operation of the pico-washer when integrated into a system, and validate this design rule experimentally. We anticipate that this technology will contribute to continued development of the droplet microfluidics toolbox and the realization of novel droplet-based, multistep biological and chemical assays.

Indexed as

EngineeringMicrofluidics

Identifiers

PMID35498338
PMCPMC9050730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.