Evidence map›Paper›PMID 35497175›Full record

ArticleRSC advances2020

Nitric oxide sensors using nanospiral ZnO thin film deposited by GLAD for application to exhaled human breath.

Pingxiang Luo, Min Xie, Jingting Luo, Hao Kan, Qiuping Wei

Open access · goldAbstract read
In one paragraph

Article in RSC advances, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 48 citations in OpenAlex.

  1. Review
  2. Review
  3. Cross-Interference of VOCs in SnONanomaterials (Basel, Switzerland) · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Pingxiang LuoFujian Maternity and Child Health Hospital, Affiliated Hospital of Fujian Medical University 350001 China.
Min XieFujian Maternity and Child Health Hospital, Affiliated Hospital of Fujian Medical University 350001 China.
Jingting LuoShenzhen Key Laboratory of Advanced Thin Films and Applications, College of Physics and Optoelectronic Engineering, Shenzhen University 518060 Shenzhen China luojt@szu.edu.cn.ORCID https://orcid.org/0000-0003-4326-982X
Hao KanShenzhen Key Laboratory of Advanced Thin Films and Applications, College of Physics and Optoelectronic Engineering, Shenzhen University 518060 Shenzhen China luojt@szu.edu.cn.
Qiuping WeiSchool of Materials Science and Engineering, State Key Laboratory of Powder Metallurgy, Central South University Changsha 410083 China.ORCID https://orcid.org/0000-0002-8109-5982
Fujian Medical University · CNShenzhen University · CNCentral South University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

ZnO is a promising gas sensing material for its excellent gas sensing response characteristics and long-term stability. Moreover, the improvement in the sensitivity and response speed of ZnO gas sensors can be achieved by the nanostructure fabrication. This paper proposes a facile method to deposit ZnO nanospirals using glancing angle deposition (GLAD) for application in nitric oxide (NO) sensors. ZnO nanospirals with porous characteristics have larger relative surface area and more active surfaces, compared with dense ZnO thin film. A sensor using nanospiral ZnO film shows a response factor of 16.9 to 100 ppb NO at 150 °C in 40% RH, which is 3 times larger than that of the sensor using dense ZnO film. Such a ZnO nanospiral sensor system can detect NO as low as 10 ppb which is below the NO concentration (>30 ppb) in exhaled breath of patients with asthma. The effects of working temperature and humidity on the sensor performance were investigated systematically in this work. Moreover, the sensor response showed a good selectivity to NO and high stability as the time increased up to 24 days. NO gas sensing mechanism was discussed in detail and nanospiral ZnO film sensors are promisingly applicable for exhaled human breath application compared with some other NO sensors.

Identifiers

PMID35497175
PMCPMC9052016
OpenAlexW3017036058

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.