Evidence map›Paper›PMID 35493267›Full record

ArticleCardiovascular digital health journal2022

Detecting paroxysmal atrial fibrillation from normal sinus rhythm in equine athletes using Symmetric Projection Attractor Reconstruction and machine learning.

Ying H Huang, Jane V Lyle, Anisa Shahira Ab Razak, Manasi Nandi, Celia M Marr, Christopher L-H Huang, Philip J Aston, Kamalan Jeevaratnam

Open access · goldAbstract read
In one paragraph

Article in Cardiovascular digital health journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Ying H HuangFaculty of Health and Medical Sciences, University of Surrey, Guildford, United Kingdom.
Jane V LyleDepartment of Mathematics, University of Surrey, Guildford, United Kingdom.
Anisa Shahira Ab RazakDepartment of Veterinary Medicine, University of Cambridge, Madingley Rd, Cambridge, United Kingdom.
Manasi NandiSchool of Cancer and Pharmaceutical Sciences, Faculty of Life Sciences & Medicine, King's College London, London, United Kingdom.
Celia M MarrRossdales Equine Hospital and Diagnostic Centre, Newmarket, United Kingdom.
Christopher L-H HuangFaculty of Health and Medical Sciences, University of Surrey, Guildford, United Kingdom.
Philip J AstonDepartment of Mathematics, University of Surrey, Guildford, United Kingdom.
Kamalan JeevaratnamFaculty of Health and Medical Sciences, University of Surrey, Guildford, United Kingdom.
University of Surrey · GBUniversity of Cambridge · GBKing's College London · GBRossdales Veterinary Surgeons · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Atrial fibrillation (AF) is a common cardiac arrhythmia in both human and equine populations. It is associated with adverse outcomes in humans and decreased athletic performance in both populations. Paroxysmal atrial fibrillation (PAF) presents with intermittent, self-terminating AF episodes, and is difficult to diagnose once sinus rhythm resumes. Objective: We aimed to detect PAF subjects from normal sinus rhythm equine electrocardiograms (ECGs) using the Symmetric Projection Attractor Reconstruction (SPAR) method to encapsulate the waveform morphology and variability as the basis of a machine learning classification. Methods: We obtained ECG signals from 139 active equine athletes (120 control, 19 with a PAF diagnosis). The SPAR method was applied to 9 short (20-second) ECG strips for each subject. An optimal SPAR feature set was determined by forward feature selection for input to a machine learning model ensemble of 3 different classifiers ( Results: Our final cross-validated classification for a subject gave an accuracy of 89.0%, sensitivity of 94.8%, specificity of 87.1%, and receiver operating characteristic area under the curve of 0.98, taking PAF as the positive class. Conclusion: The SPAR method and machine learning generated a final model with high sensitivity, suggesting that PAF can be discriminated from short equine ECG strips. This preliminary study indicated that SPAR analysis of human ECG could support patient monitoring, risk stratification, and clinical decision-making.

Indexed as

DiagnosticEquine ECG signalsMachine learningNormal sinus rhythmParoxysmal atrial fibrillationSymmetric Projection Attractor Reconstruction

Identifiers

PMID35493267
PMCPMC9043370
OpenAlexW4212951433

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.