Evidence map›Paper›PMID 35492597›Full record

ArticleFrontiers in physiology2022

Fast Speckle Noise Suppression Algorithm in Breast Ultrasound Image Using Three-Dimensional Deep Learning.

Xiaofeng Li, Yanwei Wang, Yuanyuan Zhao, Yanbo Wei

Open access · goldAbstract read
In one paragraph

Article in Frontiers in physiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 27 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Xiaofeng LiDepartment of Information Engineering, Heilongjiang International University, Harbin, China.
Yanwei WangSchool of Mechanical Engineering, Harbin Institute of Petroleum, Harbin, China.
Yuanyuan ZhaoHeilongjiang Provincial Hospital, Harbin, China.
Yanbo WeiSchool of Automatic Control Engineering, Harbin Institute of Petroleum, Harbin, China.
Harbin Institute of Petroleum · CNHeilongjiang International University · CNHeilongjiang Provincial Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The rapid development of ultrasound medical imaging technology has greatly broadened the scope of application of ultrasound, which has been widely used in the screening, diagnosis of breast diseases and so on. However, the presence of excessive speckle noise in breast ultrasound images can greatly reduce the image resolution and affect the observation and judgment of patients' condition. Therefore, it is particularly important to investigate image speckle noise suppression. In the paper, we propose fast speckle noise suppression algorithm in breast ultrasound image using three-dimensional (3D) deep learning. Firstly, according to the gray value of the breast ultrasound image, the input breast ultrasound image contrast is enhanced using logarithmic and exponential transforms, and guided filter algorithm was used to enhance the details of glandular ultrasound image, and spatial high-pass filtering algorithm was used to suppress the excessive sharpening of breast ultrasound image to complete the pre-processing of breast ultrasound image and improve the image clarity; Secondly, the pre-processed breast ultrasound images were input into the 3D convolutional cloud neural network image speckle noise suppression model; Finally, the edge sensitive terms were introduced into the 3D convolutional cloud neural network to suppress the speckle noise of breast ultrasound images while retaining image edge information. The experiments demonstrate that the mean square error and false recognition rate all reduced to below 1.2% at the 100th iteration of training, and the 3D convolutional cloud neural network is well trained, and the signal-to-noise ratio of ultrasound image speckle noise suppression is greater than 60 dB, the peak signal-to-noise ratio is greater than 65 dB, the edge preservation index value exceeds the experimental threshold of 0.45, the speckle noise suppression time is low, the edge information is well preserved, and the image details are clearly visible. The speckle noise suppression time is low, the edge information is well preserved, and the image details are clearly visible, which can be applied to the field of breast ultrasound diagnosis.

Indexed as

bootstrap filtering algorithmbreast ultrasound imageconvolutional cloud networkimage speckle suppressionthree-dimensional deep learning

Identifiers

PMID35492597
PMCPMC9043555
OpenAlexW4224033306

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.