Evidence map›Paper›PMID 35492302›Full record

ArticleFrontiers in medicine2022

Non-Invasive Monitoring of Core Body Temperature for Targeted Temperature Management in Post-Cardiac Arrest Care.

Kyle Fiorini, Tanya Tamasi, Justin Dorie, Ahmed F Hegazy, Ting-Yim Lee, Marat Slessarev

Open access · goldAbstract read
In one paragraph

Article in Frontiers in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Observational
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Kyle FioriniSchulich School of Medicine and Dentistry, Western University, London, ON, Canada.
Tanya TamasiKidney Clinical Research Unit, Lawson Health Research Institute, London, ON, Canada.
Justin DorieKidney Clinical Research Unit, Lawson Health Research Institute, London, ON, Canada.
Ahmed F HegazyDivision of Critical Care, Department of Medicine, London Health Sciences Centre, London, ON, Canada.
Ting-Yim LeeDepartment of Medical Imaging and Biophysics, Western University, London, ON, Canada.
Marat SlessarevDivision of Critical Care, Department of Medicine, London Health Sciences Centre, London, ON, Canada.
Lawson Health Research Institute · CAWestern University · CALondon Health Sciences Centre · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Accurate monitoring of core body temperature is integral to targeted temperature management (TTM) following cardiac arrest. However, there are no reliable non-invasive methods for monitoring temperature during TTM. Objectives: We compared the accuracy and precision of a novel non-invasive Zero-Heat-Flux Thermometer (SpotOn™) to a standard invasive esophageal probe in a cohort of patients undergoing TTM post-cardiac arrest. Design Setting and Participants: We prospectively enrolled 20 patients undergoing post-cardiac arrest care in the intensive care units at the London Health Sciences Centre in London, Canada. A SpotOn™ probe was applied on each patient's forehead, while an esophageal temperature probe was inserted, and both temperature readings were recorded at 1-min intervals for the duration of TTM. Main outcomes and Measures: We compared the SpotOn™ and esophageal monitors using the Bland-Altman analysis and the Pearson correlation, with accuracy set as a primary outcome. Secondary outcomes included precision and correlation. Bias exceeding 0.1°C and limits of agreement exceeding 0.5°C were considered clinically important. Results: Sixteen (80%) of patients had complete data used in the final analysis. The median (interquartile range) duration of recording was 38 (12-56) h. Compared to the esophageal probe, SpotOn™ had a bias of 0.06 ± 0.45°C and 95% limits of agreement of -0.83 to 0.95°C. The Pearson correlation coefficient was 0.97 (95% confidence interval 0.9663-0.9678), with a two-tailed Conclusion and Relevance: The SpotOn™ is an accurate method that may enable non-invasive monitoring of core body temperature during TTM, although its precision is slightly worse than the predefined 0.5°C when compared to invasive esophageal probe.

Indexed as

brain injuriescritical careheart arresthypothermiainducedtechnologythermometers

Identifiers

PMID35492302
PMCPMC9043456
OpenAlexW4225867189

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.