Evidence map›Paper›PMID 35492047›Full record

ArticleHardwareX2021

Motor-driven autonomous system for controlling beamline iris diaphragm apertures.

Daniel Pinheiro Leal, Jörg Krämer, Wilfried Nörtershäuser

Abstract read
In one paragraph

Article in HardwareX, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Daniel Pinheiro LealDivision of Engineering Science, University of Toronto, Canada.
Jörg KrämerInstitut für Kernphysik, Technische Universität Darmstadt, Germany.
Wilfried NörtershäuserInstitut für Kernphysik, Technische Universität Darmstadt, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

At the collinear apparatus for laser spectroscopy and applied sciences (COALA) at TU Darmstadt, collinear laser spectroscopy is applied to perform high-precision measurements of atomic transition frequencies and high voltages in an ultra-high vacuum beamline. In such laser spectroscopy beamlines, iris diaphragms are used to reduce ion beam divergence, and to ensure a good laser and ion beam overlap. Since the system that controls the diameter of the apertures presents strong hysteresis, an automated adjustment is desirable to enhance reproducibility in the aperture settings, and to reduce the effort in performing measurements where different diameters are required, especially in alternating collinear and anti-collinear measurements. To achieve this, the

Indexed as

ArduinoAutomated measurementsBeamlineCollinear laser spectroscopyMotorized iris diaphragm

Identifiers

PMID35492047
PMCPMC9041200

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.