ArticleBone & joint research2022
Biomechanical effect of anatomical tibial component design on load distribution of medial proximal tibial bone in total knee arthroplasty : finite element analysis indicating anatomical design prevents stress-shielding.
Article in Bone & joint research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Radiographic features of bone ingrowth in highly porous cementless total knee arthroplasty with minimum 2-year follow-up.Arthroplasty (London, England) · 2026Article
- The Effect of the Coronal Alignment of Extension Stem on Component Displacement and Stress During Total Knee Arthroplasty: A Finite Element Study.Orthopaedic surgery · 2026Article
- Does tibial sclerosis severity influence bone resorption risk following total knee arthroplasty? : finite element analysis considering implant design and surgical technique.Bone & joint research · 2026Article
- Biomechanical study on the treatment of tibial defects in total knee arthroplasty using the cement-screw and metal block with extension stem techniques: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026Article
- Survival of primary total knee arthroplasty in a modern anatomic implant with and without a short stem extension.Archives of orthopaedic and trauma surgery · 2025Article
- Optimization of Tibial Stem Geometry in Total Knee Arthroplasty Using Design of Experiments: A Finite Element Analysis.Bioengineering (Basel, Switzerland) · 2025Article
- Fixation stability and stress redistribution following metal block use in opening-wedge high tibial osteotomy: a finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- The Effects of Different Femoral Component Materials on Bone and Implant Response in Total Knee Arthroplasty: A Finite Element Analysis.Materials (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsThis study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic tibial bone of Koreans using finite element analysis (FEA).
methods3D finite element models of 30 tibiae in Korean women were created. A symmetric tibial component (STC, NexGen LPS-Flex) and an ATC (Persona) were used in surgical simulation. We compared the FEA measurements (von Mises stress and principal strains) around the stem tip and in the medial half of the proximal tibial bone, as well as the distance from the distal stem tip to the shortest anteromedial cortical bone. Correlations between this distance and FEA measurements were then analyzed.
resultsThe distance from the distal stem tip to the shortest cortical bone showed no statistically significant difference between implants. However, the peak von Mises stress around the distal stem tip was higher with STC than with ATC. In the medial half of the proximal tibial bone: 1) the mean von Mises stress, maximum principal strain, and minimum principal strain were higher with ATC; 2) ATC showed a positive correlation between the distance and mean von Mises stress; 3) ATC showed a negative correlation between the distance and mean minimum principal strain; and 4) STC showed no correlation between the distance and mean measurements.
conclusionImplant design affects the load distribution on the periprosthetic tibial bone, and ATC can be more advantageous in preventing stress-shielding than STC. However, under certain circumstances with short distances, the advantage of ATC may be offset. Cite this article:
Indexed as
Identifiers
What OpenQuestion holds
Registered trials