Evidence map›Paper›PMID 35488727›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2023

Interaction of surface topography and taper mismatch on head-stem modular junction contact mechanics during assembly in modern total hip replacement.

Jonathan A Gustafson, Steven P Mell, Brett R Levine, Robin Pourzal, Hannah J Lundberg

Abstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. In vivo assessment of TiOAnalytical and bioanalytical chemistry · 2024
    Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jonathan A GustafsonDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.ORCID 0000-0002-9786-6219
Steven P MellDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.ORCID 0000-0003-1109-9336
Brett R LevineDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
Robin PourzalDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
Hannah J LundbergDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.ORCID 0000-0002-6981-8690

Funding

Corrosion Induced Hip Implant Failure: Synergistic Interactions of Patient, Material, Design, and Surgical FactorsR01AR070181 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI LUNDBERG, HANNAH JEAN, MATHEW, MATHEW THOPPIL · 2016 to 2020
$2.3M
Preventing Total Hip Modular Junction Fretting through Optimal Surface TopographyR03AR066829 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI LUNDBERG, HANNAH JEAN · 2015 to 2017
$233k
NIAMS NIH HHS R01 AR070181NIAMS NIH HHS R03 AR066829
6 · The paper itself

Abstract

Implant failure due to fretting corrosion at the head-stem modular junction is an increasing problem in modular total hip arthroplasty. The effect of varying microgroove topography on modular junction contact mechanics has not been well characterized. The aim of this study was to employ a novel, microgrooved finite element (FEA) model of the hip taper interface and assess the role of microgroove geometry and taper mismatch angle on the modular junction mechanics during assembly. A two-dimensional, axisymmetric FEA model was created using a modern 12/14 taper design of a CoCrMo femoral head taper and Ti6Al4V stem taper. Microgrooves were modeled at the contacting interface of the tapers and varied based on height and spacing measurements obtained from a repository of measured retrievals. Additionally, taper angular mismatch between the head and stem was varied to simulate proximal- and distal-locked engagement. Forty simulations were conducted to parametrically evaluate the effects of microgroove surface topography and angular mismatch on predicted contact area, contact pressure, and equivalent plastic strain. Multiple linear regression analysis was highly significant (p < 0.001; R

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisCorrosionHumansProsthesis DesignProsthesis FailureRegression Analysisarthroplasty-hipbiomechanicsfinite element analysismodeling

Identifiers

PMID35488727
PMCPMC9617811

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked