Evidence map›Paper›PMID 35488007›Full record

ArticleScientific reports2022

Cycle-consistent adversarial networks improves generalizability of radiomics model in grading meningiomas on external validation.

Yae Won Park, Seo Jeong Shin, Jihwan Eom, Heirim Lee, Seng Chan You, Sung Soo Ahn, Soo Mee Lim, Rae Woong Park, Seung-Koo Lee

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Advancements in the application of MRI radiomics in meningioma.Radiation oncology (London, England) · 2025
    Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yae Won Park *Department of Radiology and Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, Korea.
Seo Jeong Shin *Department of Biomedical Sciences, Ajou University Graduate School of Medicine, Suwon, Republic of Korea.
Jihwan EomDepartment of Computer Science, Yonsei University, Seoul, Korea.
Heirim LeeDepartment of Biomedical Informatics, Ajou University School of Medicine, Suwon, Republic of Korea.
Seng Chan YouDepartment of Biomedical Systems Informatics, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, Korea. chandryou@yuhs.ac.
Sung Soo AhnDepartment of Radiology and Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, Korea. sungsoo@yuhs.ac.
Soo Mee LimDepartment of Radiology, Ewha Womans University College of Medicine, Seoul, Korea.
Rae Woong ParkDepartment of Biomedical Sciences, Ajou University Graduate School of Medicine, Suwon, Republic of Korea.
Seung-Koo LeeDepartment of Radiology and Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The heterogeneity of MRI is one of the major reasons for decreased performance of a radiomics model on external validation, limiting the model's generalizability and clinical application. We aimed to establish a generalizable radiomics model to predict meningioma grade on external validation through leveraging Cycle-Consistent Adversarial Networks (CycleGAN). In this retrospective study, 257 patients with meningioma were included in the institutional training set. Radiomic features (n = 214) were extracted from T2-weighted (T2) and contrast-enhanced T1 (T1C) images. After radiomics feature selection, extreme gradient boosting classifiers were developed. The models were validated in the external validation set consisting of 61 patients with meningiomas. To reduce the gap in generalization associated with the inter-institutional heterogeneity of MRI, the smaller image set style of the external validation was translated into the larger image set style of the institutional training set using CycleGAN. On external validation before CycleGAN application, the performance of the combined T2 and T1C models showed an area under the curve (AUC), accuracy, and F1 score of 0.77 (95% confidence interval 0.63-0.91), 70.7%, and 0.54, respectively. After applying CycleGAN, the performance of the combined T2 and T1C models increased, with an AUC, accuracy, and F1 score of 0.83 (95% confidence interval 0.70-0.97), 73.2%, and 0.59, respectively. Quantitative metrics (by Fréchet Inception Distance) showed that CycleGAN can decrease inter-institutional image heterogeneity while preserving predictive information. In conclusion, leveraging CycleGAN may be helpful to increase the generalizability of a radiomics model in differentiating meningioma grade on external validation.

Indexed as

Meningeal NeoplasmsMeningiomaArea Under CurveHumansMagnetic Resonance ImagingRetrospective Studies

Identifiers

PMID35488007
PMCPMC9055063

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.