Evidence map›Paper›PMID 35483328›Full record

SynthesisCardiology2022

A Review of New-Onset Ventricular Arrhythmia after Left Ventricular Assist Device Implantation.

Jianwei Shi, Xinyi Yu, Zhigang Liu

Open access · hybridAbstract readSystematic Review
In one paragraph

Synthesis in Cardiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Observational
  3. Article
  4. Article
  5. Review
  6. Article
  7. Mechanical circulatory support in ventricular arrhythmias.Frontiers in cardiovascular medicine · 2022
    Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 3 countries.

Jianwei ShiDepartment of Cardiovascular Surgery, TEDA International Cardiovascular Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.
Xinyi YuDepartment of Cardiovascular Surgery, TEDA International Cardiovascular Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.
Zhigang LiuDepartment of Cardiovascular Surgery, TEDA International Cardiovascular Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.
TEDA International Cardiovascular Hospital · CNChinese Academy of Medical Sciences & Peking Union Medical College · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionHeart failure (HF) is a severe and terminal stage of various heart diseases. Left ventricular assist devices (LVADs) are relatively mature and have contributed to the treatment of end-stage HF. Ventricular arrhythmia (VA) is a common complication after LVAD implantation, including ventricular tachycardia and ventricular fibrillation, both of which may cause abnormal circulation.

methodsA literature search was conducted in the PubMed database, "Ventricular Arrhythmia" OR "VA" OR "Arrhythmia" OR "Ventricular Tachycardia," OR "Ventricular Fibrillation" AND "LVAD" OR "Left Ventricular Assist Device" OR "Heart Assist Device" as either keywords or MeSH terms, the authors screened the titles and abstracts of the articles. Eventually, 12 original research articles were retrieved.

resultsThe 0.83 [95% CI: 0.77, 0.89] of patients were male. A whole of 53% [95% CI: 0.25, 0.81] of VA patients had a history of atrial fibrillation and 61% [95% CI: 0.52, 0.69] had a history of VA. 39% [95% CI: 0.29, 0.49] of the participants had no prior history of VA and experienced new VA following CF-LVAD implantation. Following CF-LVAD implantation, 59% [95% CI: 0.51, 0.67] of patients developed early VA (VA ≤30 days). The 30-day mortality rate of patients was 4% [95% CI: 0.01, 0.07]. And overall mortality was 28% [95% CI: 0.15, 0.41]. The reported incidence of VA after LVAD implantation is not identical in different medical centers and ranges from 20% to 60%. The mechanism of VA after LVAD implantation is summarized as primary cardiomyopathy-related, device mechanical stimulation, myocardial scarring, ventricular displacement, electrolyte regulation, and other processes.

conclusionsA preoperative VA history is considered a predictor of VA following LVAD implantation in most studies. Multiple mechanisms and factors, such as prevention of "suction events," ablation, and implantable cardioverter defibrillator, should be considered for the prevention and treatment of postoperative VA in patients requiring long-term VAD treatment. This study provides a reference for the clinical application of LAVD and the prevention of postoperative VA after LVAD implantation. Future multicenter prospective studies with uniform patient follow-up are needed to screen for additional potential risk factors and predictors. These studies will help to define the incidence rate of VA after LAVD implantation. As a result, we provide guidance for the selection of preventive intervention.

Indexed as

Arrhythmias, CardiacHeart-Assist DevicesHeart FailureFemaleHumansMaleRisk FactorsTachycardia, VentricularTreatment OutcomeVentricular FibrillationLeft ventricular assist deviceVentricular arrhythmia

Identifiers

PMID35483328
PMCPMC9393833
OpenAlexW4225146456

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked