Evidence map›Paper›PMID 35481611›Full record

ArticleJournal of applied clinical medical physics2022

Characterization of positioning uncertainties in PET-CT-MR trimodality solutions for radiotherapy.

Pauline Hinault, Isabelle Gardin, Pierrick Gouel, Pierre Decazes, Sebastien Thureau, Ovidiu Veresezan, Henri Souchay, Pierre Vera, David Gensanne

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Pauline HinaultQuantIF-LITIS EA4108, University of Rouen Normandie, Rouen, France.
Isabelle GardinQuantIF-LITIS EA4108, University of Rouen Normandie, Rouen, France.
Pierrick GouelQuantIF-LITIS EA4108, University of Rouen Normandie, Rouen, France.ORCID https://orcid.org/0000-0003-1605-7397
Pierre DecazesQuantIF-LITIS EA4108, University of Rouen Normandie, Rouen, France.
Sebastien ThureauQuantIF-LITIS EA4108, University of Rouen Normandie, Rouen, France.
Ovidiu VeresezanRadiotherapy Department, Henri Becquerel Cancer Center, Rouen, France.
Henri SouchayGE Healthcare, Buc, France.
Pierre VeraQuantIF-LITIS EA4108, University of Rouen Normandie, Rouen, France.
David GensanneQuantIF-LITIS EA4108, University of Rouen Normandie, Rouen, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to evaluate the positioning uncertainties of two PET/CT-MR imaging setups, C1 and C2. Because the PET/CT data were acquired on the same hybrid device with automatic image registration, experiments were conducted using CT-MRI data. In C1, a transfer table was used, which allowed the patient to move from one imager to another while maintaining the same position. In C2, the patient stood up and was positioned in the same radiotherapy treatment position on each imager. The two setups provided a set of PET/CT and MR images. The accuracy of the registration software was evaluated on the CT-MRI data of one patient using known translations and rotations of MRI data. The uncertainties on the two setups were estimated using a phantom and a cohort of 30 patients. The accuracy of the positioning uncertainties was evaluated using descriptive statistics and a t-test to determine whether the mean shift significantly deviated from zero (p < 0.05) for each setup. The maximum registration errors were less than 0.97 mm and 0.6° for CT-MRI registration. On the phantom, the mean total uncertainties were less than 2.74 mm and 1.68° for C1 and 1.53 mm and 0.33° for C2. For C1, the t-test showed that the displacements along the z-axis did not significantly deviate from zero (p = 0.093). For C2, significant deviations from zero were present for anterior-posterior and superior-inferior displacements. The mean total uncertainties were less than 4 mm and 0.42° for C1 and less than 1.39 mm and 0.27° for C2 in the patients. Furthermore, the t-test showed significant deviations from zero for C1 on the anterior-posterior and roll sides. For C2, there was a significant deviation from zero for the left-right displacements.This study shows that transfer tables require careful evaluation before use in radiotherapy.

Indexed as

Positron Emission Tomography Computed TomographyTomography, X-Ray ComputedHumansMagnetic Resonance ImagingPatient PositioningPhantoms, ImagingRadiotherapy Planning, Computer-Assistedmultimodality imagingpositioningradiotherapy

Identifiers

PMID35481611
PMCPMC9278679

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.