Evidence map›Paper›PMID 35481604›Full record

ArticleMagnetic resonance in medicine2022

Motion-corrected 3D-EPTI with efficient 4D navigator acquisition for fast and robust whole-brain quantitative imaging.

Zijing Dong, Fuyixue Wang, Kawin Setsompop

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Prospective motion correction forMagnetic resonance in medicine · 2025
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Zijing DongAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0001-9334-0968
Fuyixue WangAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0001-8975-2775
Kawin SetsompopDepartment of Radiology, Stanford University, Stanford, California, USA.

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Susie Yi Huang · 2020 to 2026
$10.9M
Project 4P41EB015896 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI ROSEN, BRUCE R · 2012 to 2018
$9.8M
Next generation in-vivo diffusion imaging at submillimeter resolutionR01MH116173 · NIMH · STANFORD UNIVERSITY · PI Yogesh Rathi, Kawin Setsompop · 2018 to 2026
$6.2M
fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution: Administrative SupplementR01EB019437 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO, SETSOMPOP, KAWIN · 2015 to 2024
$5.5M
Three-Dimensional Patient-Tailored RF Pulses for Spin Echo Neuroimaging at 7 TR01EB016695 · NIBIB · VANDERBILT UNIVERSITY · PI GRISSOM, WILLIAM A · 2014 to 2021
$3.8M
Rapid MRI acquisition for pediatric low-grade gliomasR01EB020613 · NIBIB · STANFORD UNIVERSITY · PI SETSOMPOP, KAWIN · 2016 to 2019
$2.5M
A Storage Area Network for Structural and Functional Image AnalysisS10RR023401 · NCRR · MASSACHUSETTS GENERAL HOSPITAL · PI FISCHL, BRUCE · 2009 to 2009
$2.0M
SILICON GRAPHICS PRISM EXTREME 128P/1TBS10RR023043 · NCRR · MASSACHUSETTS GENERAL HOSPITAL · PI SORENSEN, ALMA GREGORY · 2006 to 2006
$1.5M
Computeserver Structural &Functional Image AnalysisS10RR019307 · NCRR · MASSACHUSETTS GENERAL HOSPITAL · PI FISCHL, BRUCE · 2004 to 2004
$496k
NCRR NIH HHS S10 RR019307NCRR NIH HHS S10 RR023043NCRR NIH HHS S10 RR023401NIBIB NIH HHS P41 EB015896NIBIB NIH HHS P41 EB030006NIBIB NIH HHS R01 EB016695NIBIB NIH HHS R01 EB019437NIBIB NIH HHS R01 EB020613NIBIB NIH HHS U01 EB025162NIMH NIH HHS R01 MH116173
6 · The paper itself

Abstract

purposeTo develop a motion estimation and correction method for motion-robust three-dimensional (3D) quantitative imaging with 3D-echo-planar time-resolved imaging. THEORY AND

methodsThe 3D-echo-planar time-resolved imaging technique was designed with additional four-dimensional navigator acquisition (x-y-z-echoes) to achieve fast and motion-robust quantitative imaging of the human brain. The four-dimensional-navigator is inserted into the relaxation-recovery deadtime of the sequence in every pulse TR (∼2 s) to avoid extra scan time, and to provide continuous tracking of the 3D head motion and B

resultsSimulation shows the cost to the SNR efficiency from the added navigator acquisitions is <1%. Both simulation and in vivo retrospective experiments were conducted, that demonstrate the four-dimensional navigator provided accurate estimation of the 3D motion and B

conclusionThe proposed four-dimensional navigator acquisition provides reliable tracking of the head motion and B

Indexed as

Imaging, Three-DimensionalMagnetic Resonance ImagingArtifactsBrainHumansImage Processing, Computer-AssistedProspective StudiesRetrospective Studiesbrain imagingEPTImotion correctionnavigatorquantitative imaging

Identifiers

PMID35481604
PMCPMC9246907

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.