ArticlePakistan journal of medical sciences
Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications.
Article in Pakistan journal of medical sciences. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.
- Efficacy and safety of MIPO versus ORIF in distal tibial fractures: a systematic review and meta-analysis.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2026Pooled it
- [Treatment options and research progress of proximal tibial extra-articular fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025Review
- Cephalomedullary Nailing vs. Dynamic Hip Screw for the Treatment of Pertrochanteric Fractures: The Role of Cytokines in the Prediction of Surgical Invasiveness.Journal of clinical medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: To explore the curative effect of minimally invasive percutaneous plate osteosynthesis (MIPPO) technology combined with locking compression plates (LCP) guided by C-arm X-ray machine in the treatment of tibial metaphyseal fracture and its impact on the surgical indexes and postoperative complications. Methods: The present study was a retrospective analysis focusing on the clinical data of 104 cases of tibial metaphyseal fracture who were treated surgically in our hospital from February 2019 to February 2021. According to different surgical methods, patients who were treated by using MIPPO technology combined with LCP guided by C-arm X-ray machine were divided into the observation group (n=54), while those who underwent traditional open reduction and internal fixation were classified into the control group (n=50). Further comparison was made on the differences of the curative effect, surgical index (operation time, intraoperative blood loss, incision length, and healing time) and postoperative complications between the two groups. In addition, the differences in ankle function, knee function and quality of life [Medical Outcomes Study 36-item Short-Form Health Survey (MOS SF-36)] were evaluated between the two groups before treatment and 6 months after treatment. Results: The clinical curative effect and total efficacy of the observation group were better than those of the control group (All p<0.05). The operation time, intraoperative blood loss, incision length, and healing time were lower in the observation group when compared to those of the control group (All p<0.05). The total incidence of postoperative complications was also lower in the observation group than that in the control group (p<0.05). In addition, the scores of ankle function, knee function and MOS SF-36 in both groups were higher after 6 months of treatment than those before treatment; besides, the inter-group comparison showed that the scores of ankle function, knee function and MOS SF-36 in the observation group were higher than those in the control group (All p<0.05). Conclusion: MIPPO technology combined with LCP guided by C-arm X-ray machine has a significant curative effect on the treatment of tibial metaphyseal fracture. It can significantly improve the surgical index, reduce postoperative complications, and have an obvious effect on postoperative recovery of ankle function, knee joint function and quality of life.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.