ArticleFrontiers in medicine2022
Artificial Intelligence-Enabled Electrocardiogram Predicted Left Ventricle Diameter as an Independent Risk Factor of Long-Term Cardiovascular Outcome in Patients With Normal Ejection Fraction.
Article in Frontiers in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07163767 (Acute Myocardial Infarction Prediction Using Artificial Intelligence Applied to Electrocardiogram Images), which is not on this map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Acute Myocardial Infarction Prediction Using Artificial Intelligence Applied to Electrocardiogram Images
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.
- Deep learning and electrocardiography: systematic review of current techniques in cardiovascular disease diagnosis and management.Biomedical engineering online · 2025Pooled it
- Trial
- Bridging the gap from clinical to home ECG: quantifying and overcoming accuracy loss in AI-enabled single-lead ECG models.NPJ digital medicine · 2026Article
- Non-invasive hemoglobin estimation with outcome prediction via deep learning analysis of ECG-derived cardiac micro-dynamics.Internal and emergency medicine · 2026Article
- Detection and prognostic stratification of left ventricular systolic dysfunction in left bundle branch block using an artificial intelligence-enabled electrocardiography.Journal of cardiovascular imaging · 2026Article
- Artificial intelligence-enabled electrocardiography from scientific research to clinical application.EMBO molecular medicine · 2026Review
- Development of an Artificial Intelligence-Enabled Electrocardiography to Detect 23 Cardiac Arrhythmias and Predict Cardiovascular Outcomes.Journal of medical systems · 2025Article
- Development and validation of a machine learning model to predict myocardial blood flow and clinical outcomes from patients' electrocardiograms.Cell reports. Medicine · 2024Article
- Article
- Artificial intelligence-enabled electrocardiography contributes to hyperthyroidism detection and outcome prediction.Communications medicine · 2024Article
- Artificial Intelligence-Enabled Electrocardiography Detects B-Type Natriuretic Peptide and N-Terminal Pro-Brain Natriuretic Peptide.Diagnostics (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Heart failure (HF) is a global disease with increasing prevalence in an aging society. However, the survival rate is poor despite the patient receiving standard treatment. Early identification of patients with a high risk of HF is important but challenging. Left ventricular end-diastolic diameter (LV-D) increase was an independent risk factor of HF and adverse cardiovascular (CV) outcomes. In this study, we aimed to develop an artificial intelligence (AI) enabled electrocardiogram (ECG) system to detect LV-D increase early. Objective: We developed a deep learning model (DLM) to predict left ventricular end-diastolic and end-systolic diameter (LV-D and LV-S) with internal and external validations and investigated the relationship between ECG-LV-D and echocardiographic LV-D and explored the contributions of ECG-LV-D on future CV outcomes. Methods: Electrocardiograms and corresponding echocardiography data within 7 days were collected and paired for DLM training with 99,692 ECGs in the development set and 20,197 ECGs in the tuning set. The other 7,551 and 11,644 ECGs were collected from two different hospitals to validate the DLM performance in internal and external validation sets. We analyzed the association and prediction ability of ECG-LVD for CV outcomes, including left ventricular (LV) dysfunction, CV mortality, acute myocardial infarction (AMI), and coronary artery disease (CAD). Results: The mean absolute errors (MAE) of ECG-LV-D were 5.25/5.29, and the area under the receiver operating characteristic (ROC) curves (AUCs) were 0.8297/0.8072 and 0.9295/0.9148 for the detection of mild (56 ≦ LV-D < 65 mm) and severe (LV-D ≧ 65 mm) LV-D dilation in internal/external validation sets, respectively. Patients with normal ejection fraction (EF) who were identified as high ECHO-LV-D had the higher hazard ratios ( Conclusion: The ECG-LV-D not only identifies high-risk patients with normal EF but also serves as an independent risk factor of long-term CV outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.