ArticleCureus2022
Mechanical Valve Thrombosis Secondary to Severe Acute Respiratory Syndrome Coronavirus 2 Infection: A Case Report.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.
- Comprehensive collection of COVID-19 related prosthetic valve failure: a systematic review.Journal of thrombosis and thrombolysis · 2023Pooled it
- Risk impact of SARS-CoV-2 coronavirus and spike protein on cardiac tissue: a comprehensive review.Physiological research · 2024Review
- Successful use of ultraslow thrombolytic therapy in stuck mechanical aortic valve in a patient with COVID-19; a case report.International journal of surgery case reports · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although the association of coronavirus disease 2019 (COVID-19) and thromboembolic disease is well known, cases of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and mechanical valve thrombosis have not been described enough. Mechanical valve thrombosis is a medical emergency that is associated with a great impact on patients' morbidity and mortality. Here, we report a case of a patient with mechanical valve thrombosis secondary to SARS-CoV-2 infections that required valve replacement with satisfactory postoperative recovery. A 52-year old female patient was presented with a previously implanted mechanical prosthesis (type - St. Jude Medical 29 mm; St. Paul, MN: St. Jude Medical, Inc.) eight years ago due to rheumatic fever, under anticoagulation with warfarin and valvular atrial fibrillation (permanent), congenital single kidney (glomerular filtration rate {GFR}: 89.9 mL/min), and hypothyroidism. She was admitted to the hospital with a high level of complexity due to respiratory difficulty and generalized edematous syndrome, and a reverse transcription-polymerase chain reaction (RT-PCR) confirmed COVID-19 infection (20 days before admission); the patient was anticoagulated with warfarin (international normalized ratio {INR} at admission was 2.63 seconds). As per protocol, a CT-chest scan tomography was performed and showed organized pneumonia in the right apical lobe. We performed a transesophageal echocardiogram, which showed a thrombus (20 x 15 x 20 mm) in the lateral disc of the mechanical prosthesis, restricting its mobility. The patient presented signs of hypoperfusion (lactate levels: 4 mmol/L; urine per hour: 1 cc/kg) with associated low cardiac output syndrome, requiring double vasopressor support at the maximum dose (achieving a mean arterial pressure of 72 mmHg) due to the clinical condition and the large size of the thrombus, the cardiovascular surgeon, in agreement with the family, decides to carry out emergency valve replacement surgery with replacement of a mechanical prosthesis replacement (St. Jude No. 29; St. Paul, MN: St. Jude Medical, Inc.). The patient presented a satisfactory postoperative recovery, achieving INR goals, with subsequent discharge and follow-up at two months with transthoracic ultrasound, where normofunctional mitral prosthesis was demonstrated, without evidence of thrombi or intracavitary masses. Mechanical mitral valve thrombosis, secondary to SARS-CoV-2 infection is a serious complication with poor prognosis that requires a high rate of suspicion, and timely diagnostic aids are essential to confirm the diagnosis. Managing this issue should be interdisciplinary and individualized considering the clinical condition of the patient and the associated comorbidities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.