ArticleScientific reports2022
Bioimpedance spinal needle provides high success and low complication rate in lumbar punctures of pediatric patients with acute lymphoblastic leukemia.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.
- Lumbar puncture position in infants-a systematic review and meta-analysis.European journal of pediatrics · 2023Pooled it
- Novice providers' success in performing lumbar puncture: a randomized controlled phantom study between a conventional spinal needle and a novel bioimpedance needle.BMC medical education · 2024Trial
- Review
- A previous champagne tap reduces the probability of traumatic lumbar puncture in the following procedure.Scientific reports · 2023Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this prospective single-arm study of 50 pediatric patients with acute lymphoblastic leukemia (ALL), we evaluated the clinical performance of a novel bioimpedance spinal needle system in 152 intrathecal treatment lumbar punctures (LP) of these patients. The system detects in real-time when the needle tip reaches the cerebrospinal fluid (CSF) in the spinal canal. The success was defined as getting a CSF sample and/or administering the intrathecal treatment with one needle insertion. Incidence of traumatic LP (TLP) was defined as ≥ 10 erythrocytes/µL of CSF. Post-procedural complications were monitored with a one-week diary and one-month register follow-up. The success of the first attempt was 79.5%, with the CSF detection sensitivity of 86.1%. The incidence of TLP was 17.3%. A successful first attempt was associated with a significantly lower incidence of TLP (10% vs 40%, p = 0.0015). During the week after the procedure, the incidence of post-dural puncture headache was 6%. During the follow-up, no major complications were observed. In conclusion, the novel bioimpedance spinal needle system achieved a high success rate and low incidence of TLP and other complications in pediatric patients with ALL in a real-world clinical setting, indicating clinical utility for this system in pediatric hemato-oncology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.