Evidence map›Paper›PMID 35473932›Full record

ArticleBMC oral health2022

Digital intraoral scanner devices: a validation study based on common evaluation criteria.

Ivett Róth, Alexandra Czigola, Dóra Fehér, Viktória Vitai, Gellért Levente Joós-Kovács, Péter Hermann, Judit Borbély, Bálint Vecsei

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 2 pooled it
8.9field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 2 syntheses or guidelines pooled it, 61 citations in OpenAlex.

  1. Color Comparison Between Intraoral Scanner and Spectrophotometer Shade Matching: A Systematic Review and Meta-Analysis.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2025
    Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Comparison of trueness, time, and number of images among different denture digitization protocols.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Knowledge, attitude, and practice of digital dentures among dentists.Journal of advanced pharmaceutical technology & research · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Ivett RóthDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary. roth.ivett@dent.semmelweis-univ.hu.
Alexandra CzigolaDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary.
Dóra FehérDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary.
Viktória VitaiDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary.
Gellért Levente Joós-KovácsDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary.
Péter HermannDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary.
Judit BorbélyDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary.
Bálint VecseiDepartment of Prosthodontics, Semmelweis University, Szentkiralyi Street 47, 1088, Budapest, Hungary.
Semmelweis University · HU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe evolution of intraoral scanners (IOSs) is rapid, and new IOSs appear on the market with different properties depending on the manufacturers. There is no uniform rating system based on a defined set of aspects that has reported in the literature that can be used to compare these devices. This validation study aimed to compare different IOSs based on objective and comprehensive parameters.

methodsIn this study, 12 different IOSs were examined. The IOSs that were tested in this study in order of their delivery included the 3Shape Trios 3 Pod®, Planmeca Emerald®, Straumann DWIO®, GC Aadva®, iTero Element 2®, CEREC Primescan®, Medit i500®, 3Shape Trios 4 Move®, Carestream CS3600®, 3Shape Trios 4 Pod®, Carestream CS3700®, and Planmeca Emerald S®. IOSs were evaluated in four different ways: (a)summary chart, (b)comparative assessment, (c)data based on in vitro measurements and (d)accuracy measurements. A scoring system was created to enable an objective rating of IOSs.

resultsThe differences among IOSs were demonstrated in point scores (summary chart[max. 10 points] + weight of IOSs[max. 2.5 points] + circumference of IOSs[max. 2.5 points] + in vitro scanning time[max. 2.5 points] + pauses in data capture[max. 2.5 points] + accuracy[max. 10 points] = summary[max. 30 points]). Trios 4 Pod achieved the greatest cumulative score (23.37 points), furthermore it earned the highest points for summary chart and scanning speed. Regarding scanning continuity, the best-performing IOSs, which tied at identical point scores, were the Trios 3 and 4 Pod, Trios 4 Move, iTero Element 2, CS3600 and CS3700. The most accurate IOS was the CEREC Primescan, although it earned the lowest points of the comparative assessment (heaviest IOS). GC Aadva scored 5.73 points of a maximum of 30 points, which was the poorest result in this study.

conclusionThe scoring system reflects the differences among IOS devices based on the evaluated objective parameters and can be used to help clinicians select the right IOS device. The new generations of IOSs have more special properties, and their accuracy is higher than the previous versions. Trial registration The permission for this study was granted by University Ethics Committee of Semmelweis University (SE RKEB number:108/2019).

Indexed as

Dental Impression TechniqueModels, DentalComputer-Aided DesignDental ArchHumansImaging, Three-DimensionalDigital impression-takingIntraoral scannerValidation

Identifiers

PMID35473932
PMCPMC9044896
OpenAlexW4224981933

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.