Evidence map›Paper›PMID 35468814›Full record

ArticleBiomaterials research2022

A methylprednisolone-loaded and core-shell nanofiber-covered stent-graft to prevent inflammation and reduce degradation in aortic dissection.

Junjun Liu, Hongqiao Zhu, Yifei Pei, Heng Zhang, Jian Zhou, Zaiping Jing

Open access · goldAbstract read
In one paragraph

Article in Biomaterials research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Junjun Liu *Department of Vascular Surgery, the Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China.
Hongqiao Zhu *Department of Vascular Surgery, the First Affiliated Hospital of the Navy Medical University, Shanghai, 200433, China.
Yifei Pei *Department of Vascular Surgery, the First Affiliated Hospital of the Navy Medical University, Shanghai, 200433, China.
Heng ZhangDepartment of Vascular Surgery, the Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China.
Jian Zhou *Department of Vascular Surgery, the First Affiliated Hospital of the Navy Medical University, Shanghai, 200433, China. zhoujian1-2@163.com.
Zaiping Jing *Department of Vascular Surgery, the First Affiliated Hospital of the Navy Medical University, Shanghai, 200433, China. jingzaiping_vasc@163.com.
Affiliated Hospital of Qingdao University · CNQingdao University · CN

Funding

Dawn Project of Shanghai 19SG31Science and Technology Innovation Action Plan in Shanghai 20JC1418700the National Natural Science Foundation of China 81870366the National Natural Science Foundation of China 81900418
6 · The paper itself

Abstract

backgroundStent-graft-induced inflammation is an independent risk factor for adverse aortic remodeling in aortic dissection. In this context, we asked that whether a methylprednisolone-loaded stent-graft could reduce inflammation and degradation.

methodsFirst, a coaxial electrospinning technique was used to create a core-shell film with methylprednisolone encapsulated in the inner of poly (L-lactide-co-caprolactone) nanofibers for controllable drug release. Second, an in vitro study was conducted to evaluate the biocompatibility of the nanofiber meshes. Third, the porcine aortic dissection model was developed to investigate the therapeutic effects of the methylprednisolone-loaded stent-graft.

resultsThe results demonstrated that the nanofiber-coated film with a methylprednisolone-poly-caprolactone core layer and a poly (L-lactide-co-caprolactone) shell layer could effectively sustain drug release in vitro. In vivo study showed that the methylprednisolone-loaded stent-graft could reduce degradtion of aortic dissection by regulating inflammation.

conclusionsOverall, the controllable drug release by coaxial nanofiber is a promising approach to alleviate aortic inflammation and promote aortic remodeling after stent-graft implantation.

Indexed as

Aortic dissectionCoaxial nanofiberExtracellular matrix degradationInflammationMethylprednisolone

Identifiers

PMID35468814
PMCPMC9036796
OpenAlexW4224435108

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.