Evidence map›Paper›PMID 35464187›Full record

ArticleBiomedical signal processing and control2022

Asymptomatic COVID-19 CT image denoising method based on wavelet transform combined with improved PSO.

Guowei Wang, Shuli Guo, Lina Han, Anil Baris Cekderi, Xiaowei Song, Zhilei Zhao

Open access · greenAbstract read
In one paragraph

Article in Biomedical signal processing and control, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Guowei WangState Key Laboratory of Intelligent Control and Decision of Complex Systems, School of Automation, Beijing Institute of Technology, Beijing 100081, China.
Shuli GuoState Key Laboratory of Intelligent Control and Decision of Complex Systems, School of Automation, Beijing Institute of Technology, Beijing 100081, China.
Lina HanDepartment of Cardiology, The Second Medical Center, National Clinical Research Center for Geriatric Diseases, Chinese PLA General Hospital, Beijing, China.
Anil Baris CekderiState Key Laboratory of Intelligent Control and Decision of Complex Systems, School of Automation, Beijing Institute of Technology, Beijing 100081, China.
Xiaowei SongState Key Laboratory of Intelligent Control and Decision of Complex Systems, School of Automation, Beijing Institute of Technology, Beijing 100081, China.
Zhilei ZhaoState Key Laboratory of Intelligent Control and Decision of Complex Systems, School of Automation, Beijing Institute of Technology, Beijing 100081, China.
Beijing Institute of Technology · CNChinese PLA General Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The quality of asymptomatic corona virus disease 2019 (COVID-19) computed tomography (CT) image is reduced due to interference from Gaussian noise, which affects the subsequent image processing. Aiming at the problem that asymptomatic COVID-19 CT image often have small flake ground-glass shadow in the early lesions, and the density is low, which is easily confused with noise. A denoising method of wavelet transform with shrinkage factor is proposed. The threshold decreases with the increase of decomposition scale, and it reduces the misjudgment of signal points. In the advanced stage, the range of lesions increases, with consolidation and fibrosis in different sizes, which have similar gray value to the CT images of suspected cases. Aiming at the problems of low contrast and fuzzy boundary in the traditional wavelet transform, the threshold function based on the optimization of parameters combined with the improved particle swam optimization (PSO) is proposed, so that the parameters of wavelet threshold function can change adaptively according to the lung lobe and ground-glass lesions with fewer iterations. The simulation results show that the paper method is significantly better than other algorithms in peak signal-to-noise ratio (PSNR), signal-to-noise ratio (SNR) and mean absolute error (MSE). For example, aiming at the early asymptomatic COVID-19, compared with the comparison methods, the PSNR under the proposed method has increased by about 5 dB, the MSE has been greatly reduced, and the SNR has increased by about 6.1 dB. It can be seen that the denoising effect under the proposed method is the best.

Indexed as

Asymptomatic COVID-19Gaussian noiseParticle swarm optimization (PSO)Threshold functionWavelet transform