Evidence map›Paper›PMID 35458065›Full record

ArticleNanomaterials (Basel, Switzerland)2022

In Vitro Degradability, Microstructural Evaluation, and Biocompatibility of Zn-Ti-Cu-Ca-P Alloy.

Navaneethakrishnan Gopal, Parameswaran Palaniyandi, Palanisamy Ramasamy, Hitesh Panchal, Ahmed Mohamed Mahmoud Ibrahim, Mohammad S Alsoufi, Ammar H Elsheikh

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Navaneethakrishnan GopalDepartment of Mechanical Engineering, K. Ramakrishnan College of Technology, Tiruchirappalli 621112, India.ORCID 0000-0002-6075-9006
Parameswaran PalaniyandiDepartment of Mechanical Engineering, K. Ramakrishnan College of Technology, Tiruchirappalli 621112, India.
Palanisamy RamasamyDepartment of Electrical and Electronics Engineering, SRM Institute of Science and Technology, Chennai 603203, India.ORCID 0000-0003-0120-9087
Hitesh PanchalMechanical Engineering Department, Government Engineering College, Patan, Gujarat 384265, India.ORCID 0000-0002-3787-9712
Ahmed Mohamed Mahmoud IbrahimProduction Engineering and Mechanical Design Department, Faculty of Engineering, Minia University, Minya 61519, Egypt.ORCID 0000-0002-8054-0853
Mohammad S AlsoufiMechanical Engineering Department, College of Engineering and Islamic Architecture, Umm Al-Qura University, Makkah 24382, Saudi Arabia.ORCID 0000-0003-2576-9249
Ammar H ElsheikhProduction Engineering and Mechanical Design Department, Faculty of Engineering, Tanta University, Tanta 31733, Egypt.ORCID 0000-0003-0944-4938
Minia University · EGSRM Institute of Science and Technology · INTanta University · EGUmm al-Qura University · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

According to the modern era, zinc is one of the best replacements for human bio-implants due to its acceptable degradation, nominal degradable rate, and biocompatibility. However, alloying zinc with other nutrient metals is mandatory to improve the mechanical properties. In this research, Zn-4Ti-4Cu was alloyed with calcium and phosphorous through a powder metallurgical process to make guided bone regeneration (GBR). First, the sintering temperature of the alloy was found with the usage of thermogravimetric analysis (TGA). Tensile and compression tests showed the suitability of the alloy in strength. The microstructural characteristics were provided with EDS and SEM. The different phases of the alloy were detected with X-ray diffraction (XRD). We can clearly depict the precipitates formed and the strengthening mechanism due to titanium addition. An electrochemical corrosion (ECM) test was carried out with simulated body fluid (Hank's solution) as the electrolyte. Cytotoxicity, biocompatibility, mechanical properties, and corrosion resistance properties were studied and discussed.

Indexed as

biodegradationcell viabilitycorrosioncytocompatibilitymicrostructureZn-Ti

Identifiers

PMID35458065
PMCPMC9030046
OpenAlexW4224224133

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.