Evidence map›Paper›PMID 35457811›Full record

ArticleMicromachines2022

An Endovascular Catheterization Robotic System Using Collaborative Operation with Magnetically Controlled Haptic Force Feedback.

Xinming Li, Shuxiang Guo, Peng Shi, Xiaoliang Jin, Masahiko Kawanishi

Abstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. A Master-Follower Teleoperation System for Robotic Catheterisation: Design, Characterisation and Tracking Control.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xinming LiGraduate School of Engineering, Kagawa University, Takamatsu 761-0396, Japan.ORCID 0000-0003-1861-5751
Shuxiang GuoGraduate School of Engineering, Kagawa University, Takamatsu 761-0396, Japan.
Peng ShiGraduate School of Engineering, Kagawa University, Takamatsu 761-0396, Japan.
Xiaoliang JinGraduate School of Engineering, Kagawa University, Takamatsu 761-0396, Japan.
Masahiko KawanishiDepartment of Neurological Surgery, Kagawa University, Takamatsu 761-0793, Japan.

Funding

Japan Society for the Promotion of Science 15K2120
6 · The paper itself

Abstract

Robot-assisted technology is often used to perform endovascular catheterization surgeries, which generally depend on the flexible operability and the accurate force feedback of a robotic system. In this paper, an endovascular catheterization robotic system (ECRS) was developed to improve collaborative operation and haptic force feedback. A couple of operating handles were designed to maximize the use of the natural operations of surgeons on the master side, which is a flexible and ergonomic device. A magnetically controlled haptic force feedback structure is proposed based on hydrogel and solid magnetorheological (MR) fluid to offer a sense of haptic feedback to operators; this has potential influence on the field of force feedback. In addition, a unique tremor-reduction structure is introduced to enhance operating safety. Tracking performance experiments and in vitro experiments were conducted to evaluate the performance of the developed ECRS. According to these experimental results, the average translation-tracking error is 0.94 mm, and the average error of rotation is 0.89 degrees. Moreover, in vitro experiments demonstrated that haptic feedback has the advantage of reducing workload and shortening surgery completion time. The developed ECRS also has the benefits of inspiring other researchers to study collaborative robots and magnetically controlled feedback.

Indexed as

collaborative operationendovascular catheterization robotic system (ECRS)magnetically controlled haptic (MCH) force feedbackrobot-assisted surgery

Identifiers

PMID35457811
PMCPMC9029488

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.