Evidence map›Paper›PMID 35457561›Full record

ArticleInternational journal of environmental research and public health2022

Ability of Wearable Accelerometers-Based Measures to Assess the Stability of Working Postures.

Liangjie Guo, Junhui Kou, Mingyu Wu

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
6.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Liangjie GuoDepartment of Safety Engineering, Faculty of Engineering, China University of Geosciences, Wuhan 430074, China.ORCID 0000-0002-3677-3158
Junhui KouDepartment of Safety Engineering, Faculty of Engineering, China University of Geosciences, Wuhan 430074, China.
Mingyu WuDepartment of Safety Engineering, Faculty of Engineering, China University of Geosciences, Wuhan 430074, China.
China University of Geosciences · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the rapid development and widespread application of wearable inertial sensors in the field of human motion capture, the low-cost and non-invasive accelerometer (ACC) based measures have been widely used for working postural stability assessment. This study systematically investigated the abilities of ACC-based measures to assess the stability of working postures in terms of the ability to detect the effects of work-related factors and the ability to classify stable and unstable working postures. Thirty young males participated in this study and performed twenty-four load-holding tasks (six working postures × two standing surfaces × two holding loads), and forty-three ACC-based measures were derived from the ACC data obtained by using a 17 inertial sensors-based motion capture system. ANOVAs, t-tests and machine learning (ML) methods were adopted to study the factors’ effects detection ability and the postural stability classification ability. The results show that almost all forty-three ACC-based measures could (p < 0.05) detect the main effects of Working Posture and Load Carriage, and their interaction effects. However, most of them failed in (p ≥ 0.05) detecting Standing Surface’s main or interaction effects. Five measures could detect both main and interaction effects of all the three factors, which are recommended for working postural stability assessment. The performance in postural stability classification based on ML was also good, and the feature set exerted a greater influence on the classification accuracy than sensor configuration (i.e., sensor placement locations). The results show that the pelvis and lower legs are recommended locations overall, in which the pelvis is the first choice. The findings of this study have proved that wearable ACC-based measures could assess the stability of working postures, including the work-related factors’ effects detection ability and stable-unstable working postures classification ability. However, researchers should pay more attention to the measure selection, sensors placement, feature selection and extraction in practical applications.

Indexed as

Postural BalanceWearable Electronic DevicesAccelerometryHumansMalePostureStanding Positionbalance assessmentinertial measurement unitsmachine learningwearable accelerometersworking postural stability

Identifiers

PMID35457561
PMCPMC9030489
OpenAlexW4224039855

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.