Evidence map›Paper›PMID 35456350›Full record

ArticleJournal of clinical medicine2022

Impact of the Aortic Geometry on TAVI Prosthesis Positioning Using Self-Expanding Valves.

Philipp Breitbart, Martin Czerny, Jan Minners, Holger Schröfel, Franz-Josef Neumann, Philipp Ruile

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Philipp BreitbartDepartment of Cardiology & Angiology, University Heart Center Freiburg-Bad Krozingen, University Medical Center Freiburg, University of Freiburg, 79189 Bad Krozingen, Germany.ORCID 0000-0002-7390-5287
Martin CzernyDepartment of Cardiovascular Surgery, University Heart Center Freiburg-Bad Krozingen, University Medical Center Freiburg, University of Freiburg, 79189 Bad Krozingen, Germany.
Jan MinnersDepartment of Cardiology & Angiology, University Heart Center Freiburg-Bad Krozingen, University Medical Center Freiburg, University of Freiburg, 79189 Bad Krozingen, Germany.
Holger SchröfelDepartment of Cardiovascular Surgery, University Heart Center Freiburg-Bad Krozingen, University Medical Center Freiburg, University of Freiburg, 79189 Bad Krozingen, Germany.
Franz-Josef NeumannDepartment of Cardiology & Angiology, University Heart Center Freiburg-Bad Krozingen, University Medical Center Freiburg, University of Freiburg, 79189 Bad Krozingen, Germany.
Philipp RuileDepartment of Cardiology & Angiology, University Heart Center Freiburg-Bad Krozingen, University Medical Center Freiburg, University of Freiburg, 79189 Bad Krozingen, Germany.
University of Freiburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe impact of transcatheter heart valve (THV) position on the occurrence of paravalvular leakage and permanent pacemaker implantation caused by new-onset conduction disturbances is well described. The purpose of this study was to investigate the influence of the geometry of the thoracic aorta on the implantation depth after TAVI (transcatheter heart valve implantation) using self-expanding valve (SEV) types.

methodsWe evaluated three-dimensional geometry of the thoracic aorta based on computed tomography angiography (CTA) in 104 subsequently patients receiving TAVI with SEV devices (Evolut R). Prosthesis position was determined using the fusion imaging method of pre- and post-procedural CTA. An implantation depth of ≥4 mm was defined as the cut-off value for low prosthesis position.

resultsThe mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm below annulus plane. THV position was low in 66 (63.5%) patients and high in 38 (36.5%) patients. After multivariate adjustment none of the aortic geometry characteristics showed an independent influence on the prosthesis position-neither the Sinus of Valsalva area (

conclusionThe geometry of the thoracic aorta showed no influence on the positioning of self-expanding TAVI valve types.

Indexed as

aortic geometrycomputed tomography angiographyfusion imagingself-expanding valve typesTAVITHV positioning

Identifiers

PMID35456350
PMCPMC9025818
OpenAlexW4224245652

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.