Evidence map›Paper›PMID 35454494›Full record

ArticleMaterials (Basel, Switzerland)2022

3D-Printed Double-Helical Biodegradable Iron Suture Anchor: A Rabbit Rotator Cuff Tear Model.

Wen-Chih Liu, Chih-Hau Chang, Chung-Hwan Chen, Chun-Kuan Lu, Chun-Hsien Ma, Shin-I Huang, Wei-Lun Fan, Hsin-Hsin Shen, Pei-I Tsai, Kuo-Yi Yang and 1 more

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Wen-Chih LiuPh.D. Program in Biomedical Engineering, College of Medicine, Kaohsiung Medical University, Kaohsiung 80756, Taiwan.ORCID 0000-0001-7689-8732
Chih-Hau ChangDivision of Plastic Surgery, Department of Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung 80756, Taiwan.ORCID 0000-0001-5635-5319
Chung-Hwan ChenPh.D. Program in Biomedical Engineering, College of Medicine, Kaohsiung Medical University, Kaohsiung 80756, Taiwan.ORCID 0000-0001-8941-4792
Chun-Kuan LuDepartment of Orthopedic Surgery, Park One International Hospital, Kaohsiung 81367, Taiwan.ORCID 0000-0002-9738-6151
Chun-Hsien MaBiomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31057, Taiwan.
Shin-I HuangBiomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31057, Taiwan.
Wei-Lun FanBiomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31057, Taiwan.
Hsin-Hsin ShenBiomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31057, Taiwan.
Pei-I TsaiBiomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31057, Taiwan.ORCID 0000-0002-3516-3120
Kuo-Yi YangBiomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31057, Taiwan.
Yin-Chih FuPh.D. Program in Biomedical Engineering, College of Medicine, Kaohsiung Medical University, Kaohsiung 80756, Taiwan.
Industrial Technology Research Institute · TWKaohsiung Medical University · TWNational Sun Yat-sen University · TW

Funding

Industrial Technology Research Institute M356EX3100
6 · The paper itself

Abstract

Suture anchors are extensively used in rotator cuff tear surgery. With the advancement of three-dimensional printing technology, biodegradable metal has been developed for orthopedic applications. This study adopted three-dimensional-printed biodegradable Fe suture anchors with double-helical threads and commercialized non-vented screw-type Ti suture anchors with a tapered tip in the experimental and control groups, respectively. The in vitro study showed that the Fe and Ti suture anchors exhibited a similar ultimate failure load in 20-pound-per-cubic-foot polyurethane foam blocks and rabbit bone. In static immersion tests, the corrosion rate of Fe suture anchors was 0.049 ± 0.002 mm/year. The in vivo study was performed on New Zealand white rabbits and SAs were employed to reattach the ruptured supraspinatus tendon. The in vivo ultimate failure load of the Fe suture anchors was superior to that of the Ti suture anchors at 6 weeks. Micro-computed tomography showed that the bone volume fraction and bone surface density in the Fe suture anchors group 2 and 6 weeks after surgery were superior, and the histology confirmed that the increased bone volume around the anchor was attributable to mineralized osteocytes. The three-dimensional-printed Fe suture anchors outperformed the currently used Ti suture anchors.

Indexed as

3D printingbiodegradable metalironrabbitrotator cuffsuture anchor

Identifiers

PMID35454494
PMCPMC9027822
OpenAlexW4223428357

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked