Evidence map›Paper›PMID 35454042›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Programming Optimization in Implantable Cardiac Monitors to Reduce False-Positive Arrhythmia Alerts: A Call for Research.

Fabrizio Guarracini, Martina Testolina, Daniele Giacopelli, Marta Martin, Francesco Triglione, Alessio Coser, Silvia Quintarelli, Roberto Bonmassari, Massimiliano Marini

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Strain Imaging and Ventricular Arrhythmia.Diagnostics (Basel, Switzerland) · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Fabrizio GuarraciniDepartment of Cardiology, S. Chiara Hospital, 38122 Trento, Italy.ORCID 0000-0003-3473-1058
Martina TestolinaULSS 6 Euganea, Camposampiero, 35012 Padova, Italy.
Daniele GiacopelliClinical Unit, Biotronik Italia, Vimodrone, 20090 Milano, Italy.ORCID 0000-0003-1584-7944
Marta MartinDepartment of Cardiology, S. Chiara Hospital, 38122 Trento, Italy.
Francesco TriglioneClinical Unit, Biotronik Italia, Vimodrone, 20090 Milano, Italy.
Alessio CoserDepartment of Cardiology, S. Chiara Hospital, 38122 Trento, Italy.
Silvia QuintarelliDepartment of Cardiology, S. Chiara Hospital, 38122 Trento, Italy.
Roberto BonmassariDepartment of Cardiology, S. Chiara Hospital, 38122 Trento, Italy.
Massimiliano MariniDepartment of Cardiology, S. Chiara Hospital, 38122 Trento, Italy.
Ospedale Santa Chiara · ITMedtronic (Italy) · ITUniversity of Padua · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

No studies have investigated whether optimizing implantable cardiac monitors (ICM) programming can reduce false-positive (FP) alerts. We identified patients implanted with an ICM (BIOMONITOR III) who had more than 10 FP alerts in a 1-month retrospective period. Uniform adjustments of settings were performed based on the mechanism of FP triggers and assessed at 1 month. Eight patients (mean age 57.5 ± 23.2 years; 37% female) were enrolled. In 4 patients, FPs were caused by undersensing of low-amplitude premature ventricular contractions (PVCs). No further false bradycardia was observed with a more aggressive decay of the dynamic sensing threshold. Furthermore, false atrial fibrillation (AF) alerts decreased in 2 of 3 patients. Two patients had undersensing of R waves after high-amplitude PVCs; false bradycardia episodes disappeared or were significantly reduced by limiting the initial value of the sensing threshold. Finally, the presence of atrial ectopic activity or irregular sinus rhythm generated false alerts of AF in 2 patients that were reduced by increasing the R-R variability limit and the confirmation time. In conclusion, adjustments to nominal settings can reduce the number of FP episodes in ICM patients. More research is needed to provide practical recommendations and assess the value of extended ICM programmability.

Indexed as

cardiac arrhythmiasimplantable cardiac monitorimplantable loop recorderoversensingremote monitoringundersensing

Identifiers

PMID35454042
PMCPMC9025722
OpenAlexW4224042693

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.