Evidence map›Paper›PMID 35451494›Full record

ArticleJournal of rehabilitation medicine2022

Implanted Peroneal Nerve Stimulator Treatment for Drop Foot Caused by Central Nervous System Lesion: A Twelve-Month Follow-up of 21 Patients.

Kaare Severinsen, Kurt Grey, Anne Haase Juhl, Preben Soerensen, Lorenz Oppel, Ib Magnussen, Birgit Tine Larsen

Open access · goldAbstract read
In one paragraph

Article in Journal of rehabilitation medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Trial
  2. Review
  3. In vivo microelectrode arrays for neuroscience.Nature reviews. Methods primers · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Kaare SeverinsenHammel Neurorehabilitation Centre and University Research Clinic, Aarhus University, Denmark. kaarseve@rm.dk.
Kurt GreyDepartment of Physiotherapy and Occupational Therapy, Aalborg University Hospital, Denmark.
Anne Haase JuhlDepartment of Neurophysiology Aalborg University Hospital, Denmark.
Preben SoerensenDepartment of Neurosurgery Aalborg University Hospital.
Lorenz OppelDepartment of Physiotherapy and Occupational Therapy, Aalborg University Hospital, Denmark.
Ib MagnussenDepartment of Neurology, Aalborg University Hospital, Denmark.
Birgit Tine LarsenUniversity College of Northern Denmark (UCN) in Aalborg, Denmark.
Aalborg University Hospital · DKAarhus University · DKUniversity College of Northern Denmark · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveDrop foot is a common impairment following stroke or other causes of central pathology. We report data on patient self-perceived performance, satisfaction with performance, walking ability, and adverse effects after surgical implantation of the ActiGait® drop foot stimulator.

designProspective case study with a 12-month follow-up. SUBJECTS: Twenty-one participants with drop foot caused by central nervous system lesion.

methodsThe patients' self-perceived performance and satisfaction with performance were evaluated using the Canadian Occupational Performance Measure (COPM). Walking ability was assessed using a 10-m walk test and a 6-min walk. Nerve conduction of the peroneal nerve was examined in 10 patients.

resultsAt follow-up, COPM self-percieved performance from 3.2 to 6.7 points, the median increase being 2.8 (interquartile range (IQR) 2.2-5.0), p < 0.001. Likewise, the COPM satisfaction with performance increased from 2.6 to 6.9 points, the median increase being 4.2 (IQR 2.8-5.8), p < 0.001. Walking velocity increased 0.1 m/s from a baseline measurement of 0.73 m/s (95% confidence interval (95% CI) 0.03-0.2), n = 21, p < 0.01, and walking distance increased by 33 m, from a baseline measurement of 236 m (95% CI 15-51), n = 21, p < 0.001.

conclusionStimulation of the peroneal nerve by an implantable stimulator increases self-perceived performance, satisfaction with performance, and ambulation in patients with long-lasting drop foot caused by a central nervous system lesion.

Indexed as

Electric Stimulation TherapyGait Disorders, NeurologicCanadaCentral Nervous SystemElectrodes, ImplantedFollow-Up StudiesHumansPeroneal NerveTreatment Outcome

Identifiers

PMID35451494
PMCPMC9252092
OpenAlexW4224241754

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked