Evidence map›Paper›PMID 35450825›Full record

ArticleBiophysical journal2022

Muscle active force-length curve explained by an electrophysical model of interfilament spacing.

Robert Rockenfeller, Michael Günther, Scott L Hooper

Open access · greenAbstract read
In one paragraph

Article in Biophysical journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
4.1field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. A theory of physiological similarity in muscle-driven motion.Proceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Robert RockenfellerMathematisches Institut, Universität Koblenz-Landau, Koblenz, Germany. Electronic address: rrockenfeller@uni-koblenz.de.
Michael GüntherBiomechanics and Biorobotics, Stuttgart Center for Simulation Sciences (SC SimTech), Universität Stuttgart, Stuttgart, Germany; Friedrich-Schiller-Universität, Jena, Germany.
Scott L HooperNeuroscience Program, Department of Biological Sciences, Ohio University, Athens, Ohio.
Ohio University · USUniversity of Koblenz and Landau · DEUniversity of Stuttgart · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The active isometric force-length relation (FLR) of striated muscle sarcomeres is central to understanding and modeling muscle function. The mechanistic basis of the descending arm of the FLR is well explained by the decreasing thin:thick filament overlap that occurs at long sarcomere lengths. The mechanistic basis of the ascending arm of the FLR (the decrease in force that occurs at short sarcomere lengths), alternatively, has never been well explained. Because muscle is a constant-volume system, interfilament lattice distances must increase as sarcomere length shortens. This increase would decrease thin and thick-filament electrostatic interactions independently of thin:thick filament overlap. To examine this effect, we present here a fundamental, physics-based model of the sarcomere that includes filament molecular properties, calcium binding, sarcomere geometry including both thin:thick filament overlap and interfilament radial distance, and electrostatics. The model gives extremely good fits to existing FLR data from a large number of different muscles across their entire range of measured activity levels, with the optimized parameter values in all cases lying within anatomically and physically reasonable ranges. A local first-order sensitivity analysis (varying individual parameters while holding the values of all others constant) shows that model output is most sensitive to a subset of model parameters, most of which are related to sarcomere geometry, with model output being most sensitive to interfilament radial distance. This conclusion is supported by re-running the fits with only this parameter subset being allowed to vary, which increases fit errors only moderately. These results show that the model well reproduces existing experimental data, and indicate that changes in interfilament spacing play as central a role as changes in filament overlap in determining the FLR, particularly on its ascending arm.

Indexed as

CytoskeletonSarcomeresMechanical PhenomenaMuscle ContractionMuscle, Skeletal

Identifiers

PMID35450825
PMCPMC9199101
OpenAlexW4224219099

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.