Evidence map›Paper›PMID 35450147›Full record

ArticleApplied bionics and biomechanics2022

Research on Protection Performance of Surge Protective Devices against Electromagnetic Pulse.

Zhongyi Zhao, Shenyu Wang, Yongzhi Cui

RetractedOpen access · goldAbstract readRetracted Publication
In one paragraph

Article in Applied bionics and biomechanics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Zhongyi ZhaoFaculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, 121001 Liaoning, China.ORCID https://orcid.org/0000-0002-3789-8526
Shenyu WangFaculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, 121001 Liaoning, China.
Yongzhi CuiFaculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, 121001 Liaoning, China.
Liaoning University of Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To evaluate the protection performance of SPD (surge protective device) against electromagnetic pulse, the response ability of several typical surge protective devices to wide and narrow electromagnetic pulses was tested by using a SPD response ability test system. The results showed that SPD commonly used in lightning surge protection had certain ability to suppress electromagnetic pulse conduction disturbance. Gas discharge tubes presented typical clamping characteristics for wide pulses. MOV and TVS had obvious clamping effect on wide pulses, while had no clamping effect on narrow pulses, but could obviously reduce its peak value. Zener diodes had obvious clamping effect on narrow pulses, and the clamping voltage control accuracy was high.

Identifiers

PMID35450147
PMCPMC9017591
OpenAlexW4223647422

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.