ArticleTomography (Ann Arbor, Mich.)2022
Effect of Cardiac Phase on Cardiac Output Index Derived from Dynamic CT Myocardial Perfusion Imaging.
Article in Tomography (Ann Arbor, Mich.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Pulmonary CT perfusion robustly measures cardiac output in the context of multilevel pulmonary occlusion: a porcine study.European radiology experimental · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The aortic time-enhancement curve obtained from dynamic CT myocardial perfusion imaging can be used to derive the cardiac output (CO) index based on the indicator dilution principle. The objective of this study was to investigate the effect of cardiac phase at which CT myocardial perfusion imaging is triggered on the CO index measurement with this approach. Methods: Electrocardiogram (ECG) gated myocardial perfusion imaging was performed on farm pigs with consecutive cardiac axial scans using a large-coverage CT scanner (Revolution, GE Healthcare) after intravenous contrast administration. Multiple sets of dynamic contrast-enhanced (DCE) cardiac images were reconstructed retrospectively from 30% to 80% R-R intervals with a 5% phase increment. The time-enhancement curve sampled from above the aortic orifice in each DCE image set was fitted with a modified gamma variate function (MGVF). The fitted curve was then normalized to the baseline data point unaffected by the streak artifact emanating from the contrast solution in the right heart chamber. The Stewart−Hamilton equation was used to calculate the CO index based on the integral of the fitted normalized aortic curve, and the results were compared among different cardiac phases. Results: The aortic time-enhancement curves sampled at different cardiac phases were different from each other, especially in the baseline portion of the curve where the effect of streak artifact was prominent. After properly normalizing and denoising with a MGVF, the integrals of the aortic curve were minimally different among cardiac phases (0.228 ± 0.001 Hounsfield Unit × second). The corresponding mean CO index was 4.031 ± 0.028 L/min. There were no statistical differences in either the integral of the aortic curve or CO index among different cardiac phases (p > 0.05 for all phases).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.