Evidence map›Paper›PMID 35448305›Full record

ArticleBiosensors2022

Optimization Strategies Used for Boosting Piezoelectric Response of Biosensor Based on Flexible Micro-ZnO Composites.

Xiaoting Zhang, Jose Villafuerte, Vincent Consonni, Eirini Sarigiannidou, Jean-Fabien Capsal, Alexis Bruhat, Daniel Grinberg, Lionel Petit, Pierre-Jean Cottinet, Minh-Quyen Le

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Xiaoting ZhangElectrical Department, LGEF, Université Lyon, INSA-Lyon, EA682, F-69621 Villeurbanne, France.
Jose VillafuerteCNRS, Grenoble INP, LMGP, Université Grenoble Alpes, F-38000 Grenoble, France.ORCID 0000-0003-0207-1083
Vincent ConsonniCNRS, Grenoble INP, LMGP, Université Grenoble Alpes, F-38000 Grenoble, France.ORCID 0000-0003-0171-8746
Eirini SarigiannidouCNRS, Grenoble INP, LMGP, Université Grenoble Alpes, F-38000 Grenoble, France.
Jean-Fabien CapsalElectrical Department, LGEF, Université Lyon, INSA-Lyon, EA682, F-69621 Villeurbanne, France.ORCID 0000-0003-2904-8422
Alexis BruhatDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
Daniel GrinbergElectrical Department, LGEF, Université Lyon, INSA-Lyon, EA682, F-69621 Villeurbanne, France.
Lionel PetitElectrical Department, LGEF, Université Lyon, INSA-Lyon, EA682, F-69621 Villeurbanne, France.
Pierre-Jean CottinetElectrical Department, LGEF, Université Lyon, INSA-Lyon, EA682, F-69621 Villeurbanne, France.
Minh-Quyen LeElectrical Department, LGEF, Université Lyon, INSA-Lyon, EA682, F-69621 Villeurbanne, France.ORCID 0000-0001-5907-159X
Université Claude Bernard Lyon 1 · FRInstitut polytechnique de Grenoble · FRIcahn School of Medicine at Mount Sinai · US

Funding

Conduits: Mount Sinai Health System Translational Science HubUL1TR004419 · NCATS · ICAHN SCHOOL OF MEDICINE AT MOUNT SINAI · PI Rosalind J Wright · 2022 to 2026
$46.4M
MSHS Translational Science HubUL1TR001433 · NCATS · ICAHN SCHOOL OF MEDICINE AT MOUNT SINAI · PI WRIGHT, ROSALIND J · 2015 to 2019
$26.6M
NCATS NIH HHS UL1 TR001433NCATS NIH HHS UL1 TR004419
6 · The paper itself

Abstract

Piezoelectric ZnO-based composites have been explored as a flexible and compact sensor for the implantable biomedical systems used in cardio surgery. In this work, a progressive development route was investigated to enhance the performance of piezoelectric composites incorporated with different shape, concentration and connectivity of ZnO fillers. ZnO microrods (MRs) have been successfully synthesized homogeneously in aqueous solution using a novel process-based on chemical bath deposition (CBD) method. The morphological analysis along with Raman scattering and cathodoluminescence spectroscopy of ZnO MRs confirm their high crystalline quality, their orientation along the polar

Indexed as

Biosensing TechniquesZinc OxideSpectrum Analysis, RamanZinc Oxidecharacterizationdielectrophoresisflexible ZnO compositesmedical applicationmicro-rod/particlespiezoelectric biosensorsimulationsynthesis-based chemical bath deposition

Identifiers

PMID35448305
PMCPMC9029272
OpenAlexW4224139145

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.