Performance Characteristics of a Novel 3D-Printed Bubble Intermittent Mandatory Ventilator (B-IMV) for Adult Pulmonary Support.

Jonathan A Poli, Christopher Howard, Alfredo J Garcia, Don Remboski, Peter B Littlewood, John P Kress, Narayanan Kasthuri, Alia Comai, Kiran Soni, Philip Kennedy and 2 more

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 1 country.

Jonathan A PoliCenter for Integrative Brain Research, Seattle Children's Research Institute, Seattle, WA 98101, USA.
Christopher HowardMedical Sensor Systems, Seattle, WA 98126, USA.
Alfredo J GarciaDivision of the Biological Sciences, University of Chicago, Chicago, IL 60637, USA.
Don RemboskiNeapco Holdings, LLC, Farmington Hills, MI 48336, USA.
Peter B LittlewoodDivision of the Biological Sciences, University of Chicago, Chicago, IL 60637, USA.
John P KressDivision of the Biological Sciences, University of Chicago, Chicago, IL 60637, USA.
Narayanan KasthuriDivision of the Biological Sciences, University of Chicago, Chicago, IL 60637, USA.ORCID 0000-0003-3825-931X
Alia ComaiNeapco Holdings, LLC, Farmington Hills, MI 48336, USA.
Kiran SoniNeapco Holdings, LLC, Farmington Hills, MI 48336, USA.
Philip KennedyNeapco Holdings, LLC, Farmington Hills, MI 48336, USA.
John OggerNeapco Holdings, LLC, Farmington Hills, MI 48336, USA.
Robert M DiBlasiCenter for Integrative Brain Research, Seattle Children's Research Institute, Seattle, WA 98101, USA.
University of Chicago · USSeattle Children's Hospital · USSensor Electronics (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The COVID-19 pandemic has brought attention to the need for developing effective respiratory support that can be rapidly implemented during critical surge capacity scenarios in healthcare settings. Lung support with bubble continuous positive airway pressure (B-CPAP) is a well-established therapeutic approach for supporting neonatal patients. However, the effectiveness of B-CPAP in larger pediatric and adult patients has not been addressed. Using similar principles of B-CPAP pressure generation, application of intermittent positive pressure inflations above CPAP could support gas exchange and high work of breathing levels in larger patients experiencing more severe forms of respiratory failure. This report describes the design and performance characteristics of the BubbleVent, a novel 3D-printed valve system that combined with commonly found tubes, hoses, and connectors can provide intermittent mandatory ventilation (IMV) suitable for adult mechanical ventilation without direct electrification. Testing of the BubbleVent was performed on a passive adult test lung model and compared with a critical care ventilator commonly used in tertiary care centers. The BubbleVent was shown to deliver stable PIP and PEEP levels, as well as timing control of breath delivery that was comparable with a critical care ventilator.

Indexed as

additive manufacturingbubble continuous airway pressureventilator

Identifiers

PMID35447711
PMCPMC9027535
OpenAlexW4224324516

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.