Evidence map›Paper›PMID 35446173›Full record

ArticleGlobal spine journal2024

The Performance of MAGEC X Spine Rods: A Comparative Retrieval Study.

Martina Tognini, Harry Hothi, Sean Bergiers, Masood Shafafy, Stewart Tucker, Edel Broomfield, Johann Henckel, Alister Hart

Open access · goldAbstract read
In one paragraph

Article in Global spine journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Measurement of the wear volumes generated within retrieved magnetically controlled growing rods.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Martina TogniniThe Royal National Orthopaedic Hospital and Institute of Orthopaedics and Musculoskeletal Science, University College London, Stanmore, UK.ORCID 0000-0003-0895-0089
Harry HothiThe Royal National Orthopaedic Hospital and Institute of Orthopaedics and Musculoskeletal Science, University College London, Stanmore, UK.
Sean BergiersThe Royal National Orthopaedic Hospital and Institute of Orthopaedics and Musculoskeletal Science, University College London, Stanmore, UK.
Masood ShafafyDepartment of Trauma and Orthopaedics, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Stewart TuckerGreat Ormond Street Hospital for Children NHS Foundation Trust, London, UK.
Edel BroomfieldGreat Ormond Street Hospital for Children NHS Foundation Trust, London, UK.
Johann HenckelThe Royal National Orthopaedic Hospital and Institute of Orthopaedics and Musculoskeletal Science, University College London, Stanmore, UK.
Alister HartThe Royal National Orthopaedic Hospital and Institute of Orthopaedics and Musculoskeletal Science, University College London, Stanmore, UK.
Royal National Orthopaedic Hospital · GBGreat Ormond Street Hospital for Children NHS Foundation Trust · GBNottingham University Hospitals NHS Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designMulticentre comparative analysis of explanted Spine Magnetically Controlled Growing Rods (MCGRs).

objectivesMAGEC X, the latest commercially available generation, was recalled in 2020 due to the risk of post-implantation separation of an actuator end-cap component. Currently, the supply of all MAGEC rods was temporarily suspended in the UK and the EU. Objective of this study is to compare the performance of the MAGEC X MCGR to the earlier MAGEC 1.3 design iteration, by means of retrieval analysis.

methodsFifteen of both MAGEC X and MAGEC 1.3 rods were consecutively collected from five different hospitals following removal surgery and matched by time to removal. Clinical and implant data was collected for all MCGRs. Analysis comprised visual assessments of external damage, plain radiograph evaluations, force and elongation testing, MAGEC X end-cap torque testing and disassembly. Mann-Whitney U tests were used to statistically compare groups.

resultsRod distraction reached in vivo was significantly higher in the MAGEC 1.3 (

conclusionMAGEC X showed similar performance results than the previous design iteration MAGEC 1.3. End-cap component loosening was observed, with no major consequences on the internal mechanism.

Indexed as

MAGEC Xmagnetically controlled growing rodretrieval analysis

Identifiers

PMID35446173
PMCPMC10676182
OpenAlexW4224262471

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.