Evidence map›Paper›PMID 35445203›Full record

ArticleInnovation (Cambridge (Mass.))2022

Energy saving thermal adaptive liquid gating system.

Baiyi Chen, Mengchuang Zhang, Yaqi Hou, Huimeng Wang, Rongrong Zhang, Yi Fan, Xinyu Chen, Xu Hou

Abstract read
In one paragraph

Article in Innovation (Cambridge (Mass.)), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Taming heat with tiny pressure.Innovation (Cambridge (Mass.)) · 2024
    Article
  5. Article
  6. The Rising Aerogel Fibers: Status, Challenges, and Opportunities.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Baiyi ChenState Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Mengchuang ZhangDepartment of Physics, Research Institute for Biomimetics and Soft Matter, Fujian Provincial Key Laboratory for Soft Functional Materials Research, Jiujiang Research Institute, College of Physical Science and Technology, Xiamen University, Xiamen 361005, China.
Yaqi HouState Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Huimeng WangState Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Rongrong ZhangState Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Yi FanState Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Xinyu ChenCollege of Ocean and Earth Sciences, Carbon Neutral Innovation Research Center (CNIR), Xiamen University, Xiamen 361005, China.
Xu HouState Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Thermal transfer systems involving temperature control through heating, ventilation, and air conditioning applications have emerged as one of the largest energy issues in buildings. Traditional approaches mainly comprise closed and open systems, both of which have certain advantages and disadvantages in a single heating or cooling process. Here we report a thermal adaptive system with beneficial energy-saving properties, which uses functional liquid to exhibit high metastability, providing durability in a temperature-responsive liquid gating system. With an efficient use of energy, this system achieves smart "breathing" during both heating and cooling processes to dynamically tune the indoor temperature. Theoretical modeling and experiments demonstrate that the adaptive, sandwich-structured, membrane-based system can achieve temperature control, producing obvious advantages of energy saving compared with both closed and open systems through the bistable interfacial design of the liquid gating membrane. Further energy saving evaluation of the system on the basis of simulation with current global greenhouse plantation data shows a reduction of energy consumption of 7.9 × 10

Indexed as

energy savingfluid temperature controlgreenhouseliquid gatingthermal adaptive

Identifiers

PMID35445203
PMCPMC9014441

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.