Evidence map›Paper›PMID 35444226›Full record

ArticleScientific reports2022

Numerical mesoscale tissue model of electrochemotherapy in liver based on histological findings.

Helena Cindric, Gorana Gasljevic, Ibrahim Edhemovic, Erik Brecelj, Jan Zmuc, Maja Cemazar, Alenka Seliskar, Damijan Miklavcic, Bor Kos

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Helena CindricFaculty of Electrical Engineering, University of Ljubljana, Trzaska cesta 25, 1000, Ljubljana, Slovenia.ORCID 0000-0001-5962-6858
Gorana GasljevicInstitute of Oncology Ljubljana, Zaloska cesta 2, 1000, Ljubljana, Slovenia.ORCID 0000-0002-8332-3627
Ibrahim EdhemovicInstitute of Oncology Ljubljana, Zaloska cesta 2, 1000, Ljubljana, Slovenia.ORCID 0000-0001-8122-7896
Erik BreceljInstitute of Oncology Ljubljana, Zaloska cesta 2, 1000, Ljubljana, Slovenia.ORCID 0000-0001-7275-1557
Jan ZmucInstitute of Oncology Ljubljana, Zaloska cesta 2, 1000, Ljubljana, Slovenia.ORCID 0000-0002-0332-9843
Maja CemazarInstitute of Oncology Ljubljana, Zaloska cesta 2, 1000, Ljubljana, Slovenia.ORCID 0000-0002-1418-1928
Alenka SeliskarUniversity of Ljubljana, Veterinary Faculty, Gerbiceva ulica 60, 1000, Ljubljana, Slovenia.ORCID 0000-0003-3602-9182
Damijan MiklavcicFaculty of Electrical Engineering, University of Ljubljana, Trzaska cesta 25, 1000, Ljubljana, Slovenia.ORCID 0000-0003-3506-9449
Bor KosFaculty of Electrical Engineering, University of Ljubljana, Trzaska cesta 25, 1000, Ljubljana, Slovenia. bor.kos@fe.uni-lj.si.ORCID 0000-0001-6219-7046
University of Ljubljana · SIInstitute of Oncology Ljubljana · SIUniversity of Primorska · SI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrochemotherapy (ECT) and irreversible electroporation (IRE) are being investigated for treatment of hepatic tumours. The liver is a highly heterogeneous organ, permeated with a network of macro- and microvasculature, biliary tracts and connective tissue. The success of ECT and IRE depends on sufficient electric field established in whole target tissue; therefore, tissue heterogeneity may affect the treatment outcome. In this study, we investigate electroporation in the liver using a numerical mesoscale tissue model. We numerically reconstructed four ECT experiments in healthy porcine liver and computed the electric field distribution using our treatment planning framework. We compared the computed results with histopathological changes identified on microscopic images after treatment. The mean electric field threshold that best fitted the zone of coagulation necrosis was 1225 V/cm, while the mean threshold that best fitted the zone of partially damaged liver parenchyma attributed to IRE was 805 V/cm. We evaluated how the liver macro- and microstructures affect the electric field distribution. Our results show that the liver microstructure does not significantly affect the electric field distribution on the level needed for treatment planning. However, major hepatic vessels and portal spaces significantly affect the electric field distribution, and should be considered when planning treatments.

Indexed as

ElectrochemotherapyLiver NeoplasmsAnimalsElectricityElectroporationSwine

Identifiers

PMID35444226
PMCPMC9021251
OpenAlexW4224210091

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.