Evidence map›Paper›PMID 35439125›Full record

ArticleIEEE transactions on bio-medical engineering2022

Denoise Functional Magnetic Resonance Imaging With Random Matrix Theory Based Principal Component Analysis.

Wei Zhu, Xiaodong Ma, Xiao-Hong Zhu, Kamil Ugurbil, Wei Chen, Xiaoping Wu

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Robust-tedana: An automated denoising pipeline for multi-echo fMRI data.bioRxiv : the preprint server for biology · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Wei Zhu
Xiaodong Ma
Xiao-Hong Zhu
Kamil Ugurbil
Wei Chen
Xiaoping Wu
University of Minnesota · US

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger · 2019 to 2026
$11.7M
Elementary Neuronal Ensembles to Whole Brain Networks: Ultrahigh Resolution Imaging of Function and Connectivity in Humans - SUPPLEMENTU01EB025144 · NIBIB · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2017 to 2022
$9.7M
Breaking Spatiotemporal Barriers of MR Imaging Technologies to Study Human Brain Function and NeuroenergeticsU01EB026978 · NIBIB · UNIVERSITY OF MINNESOTA · PI CHEN, WEI, ZHU, XIAO-HONG · 2018 to 2022
$6.4M
Integrated fMRI Methods to Study Neurophysiology and Circuit Dynamics at Laminar and Columnar LevelR01MH111413 · NIMH · UNIVERSITY OF MINNESOTA · PI CHEN, WEI · 2016 to 2020
$4.4M
Institutional Center Cores for Advanced NeuroimagingP30NS076408 · NINDS · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2012 to 2020
$4.2M
Advancing simultaneous fMRI-multiphoton imaging technique to study brain function and connectivity across different scales at ultrahigh fieldR01NS118330 · NINDS · UNIVERSITY OF MINNESOTA · PI CHEN, WEI, CUI, MENG · 2020 to 2024
$2.7M
NIBIB NIH HHS P41 EB027061NIBIB NIH HHS U01 EB025144NIBIB NIH HHS U01 EB026978NIMH NIH HHS R01 MH111413NINDS NIH HHS P30 NS076408NINDS NIH HHS R01 NS118330
6 · The paper itself

Abstract

High-resolution functional MRI (fMRI) is largely hindered by random thermal noise. Random matrix theory (RMT)-based principal component analysis (PCA) is promising to reduce such noise in fMRI data. However, there is no consensus about the optimal strategy and practice in implementation. In this work, we propose a comprehensive RMT-based denoising method that consists of 1) rank and noise estimation based on a set of newly derived multiple criteria, and 2) optimal singular value shrinkage, with each module explained and implemented based on the RMT. By incorporating the variance stabilizing approach, the denoising method can deal with low signal-to-noise ratio (SNR) (such as <5) magnitude fMRI data with favorable performance compared to other state-of-the-art methods. Results from both simulation and in-vivo high-resolution fMRI data show that the proposed denoising method dramatically improves image restoration quality, promoting functional sensitivity at the same level of functional mapping blurring compared to existing denoising methods. Moreover, the denoising method can serve as a drop-in step in data preprocessing pipelines along with other procedures aimed at removal of structured physiological noises. We expect that the proposed denoising method will play an important role in leveraging high-quality, high-resolution task fMRI, which is desirable in many neuroscience and clinical applications.

Indexed as

AlgorithmsMagnetic Resonance ImagingBrainComputer SimulationImage Processing, Computer-AssistedPrincipal Component AnalysisSignal-To-Noise Ratio

Identifiers

PMID35439125
PMCPMC9579216
OpenAlexW4224281642

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.