Evidence map›Paper›PMID 35438959›Full record

ArticleACS sensors2022

Attomolar Sensitivity in Single Biomarker Counting upon Aqueous Two-Phase Surface Enrichment.

Zi Li, Molly McNeely, Erin Sandford, Muneesh Tewari, Alexander Johnson-Buck, Nils G Walter

Open access · greenAbstract read
In one paragraph

Article in ACS sensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Zi LiSingle Molecule Analysis Group, Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
Molly McNeelySingle Molecule Analysis Group, Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
Erin SandfordDepartment of Internal Medicine, Division of Hematology/Oncology, University of Michigan, Ann Arbor, Michigan 48109, United States.ORCID 0000-0003-3498-8144
Muneesh TewariDepartment of Internal Medicine, Division of Hematology/Oncology, University of Michigan, Ann Arbor, Michigan 48109, United States.
Alexander Johnson-BuckSingle Molecule Analysis Group, Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.ORCID 0000-0003-3748-6000
Nils G WalterSingle Molecule Analysis Group, Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.ORCID 0000-0002-7301-1275
University of Michigan · US

Funding

The RNA nanomachines of the gene expression machinery dissected at the single molecule levelR35GM131922 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NILS G WALTER · 2019 to 2026
$6.9M
Optimization and Validation of Single-Molecule Kinetic Fingerprinting Technology for Rapid, Ultra-Specific Detection of Cancer MutationsR33CA229023 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI TEWARI, MUNEESH, WALTER, NILS G · 2018 to 2020
$1.2M
Highly specific, amplification-free, single-molecule counting of rare methylated DNA cancer biomarkersR21CA225493 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI TEWARI, MUNEESH, WALTER, NILS G · 2020 to 2020
$609k
NCI NIH HHS R21 CA225493NCI NIH HHS R33 CA229023NIGMS NIH HHS R35 GM131922
6 · The paper itself

Abstract

From longstanding techniques like enzyme-linked immunosorbent assay (ELISA) to modern next-generation sequencing, many of the most sensitive and specific biomarker detection assays require capture of the analyte at a surface. While surface-based assays provide advantages, including the ability to reduce background by washing away excess reagents and/or increase specificity through analyte-specific capture probes, the limited efficiency of capture from dilute solution often restricts assay sensitivity to the femtomolar-to-nanomolar range. Although assays for many nucleic acid analytes can decrease limits of detection (LODs) to the subfemtomolar range using polymerase chain reaction, such amplification may introduce biases, errors, and an increased risk of sample cross-contamination. Furthermore, many analytes cannot be amplified easily, including short nucleic acid fragments, epigenetic modifications, and proteins. To address the challenge of achieving subfemtomolar LODs in surface-based assays without amplification, we exploit an aqueous two-phase system (ATPS) to concentrate target molecules in a smaller-volume phase near the assay surface, thus increasing capture efficiency compared to passive diffusion from the original solution. We demonstrate the utility of ATPS-enhanced capture via single molecule recognition through equilibrium Poisson sampling (SiMREPS), a microscopy technique previously shown to possess >99.9999% detection specificity for DNA mutations but an LOD of only ∼1-5 fM. By combining ATPS-enhanced capture with a Förster resonance energy transfer (FRET)-based probe design for rapid data acquisition over many fields of view, we improve the LOD ∼ 300-fold to <10 aM for an

Indexed as

Nucleic AcidsBiomarkersFluorescence Resonance Energy TransferHumansLimit of DetectionNanotechnologyBiomarkersNucleic Acidsaqueous two-phase systemFörster resonance energy transferkinetic fingerprintingsingle-molecule fluorescence microscopytarget enrichmentultrasensitive detection

Identifiers

PMID35438959
PMCPMC12926873
OpenAlexW4224218447

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.