ArticlePhysical and engineering sciences in medicine2022
Reducing ExacTrac intrafraction imaging uncertainty for prostate stereotactic body radiotherapy using a pre-treatment CBCT.
Article in Physical and engineering sciences in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Dynamic intrafractional position monitoring with implanted fiducial markers for enhanced accuracy in radiotherapy of prostate cancer.Physical and engineering sciences in medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study evaluated the intrafractional auto-matching uncertainties of prostate-implanted fiducial markers when using the ExacTrac v6.5 (Brainlab, Feldkirchen, Germany) X-ray stereoscopic system. A customised phantom with 3 implanted gold seeds was initially positioned at the isocentre using a cone beam CT (CBCT) prior to intrafractional imaging. Progressive offsets were applied to the phantom in all six directions (3 translational, 3 rotational) of 0 mm, 1 mm, 2 mm, 0°, 1° and 2°. Subsequently, the ability of the ExacTrac image-matching functions to detect and correct these offsets was tested. For comparison, this procedure was repeated, but without a CBCT for pre-treatment positioning. The auto-matching uncertainties when a CBCT was introduced into the workflow were significantly reduced, and overall, the auto-matching statistics using the implanted marker (seeds) matching function was found to be more precise than the bony anatomy function in-phantom. The total standard deviations for the translational shifts using the implanted marker and bony anatomy functions respectively were 0.1 mm and 0.3 mm vertically, 0.1 mm and 0.3 mm longitudinally, and 0.1 mm and 0.4 mm laterally. The standard deviations for the rotational shifts using the implanted marker and bony anatomy matching functions respectively were 0.2° and 1.2° for the yaw (angle vert), 0.3° and 1.1° for the pitch (angle long), and 0.2° and 1.2° for the roll (angle lat) directions. The reduced uncertainties from introducing a CBCT for initial localisation resulted in decreased probability of inhibits due to false positives during treatment.