Evidence map›Paper›PMID 35437707›Full record

ArticleAbdominal radiology (New York)2022

Shear wave elastography of the spleen using elastography point quantification: stiffness values in healthy children.

Anmol Bhatia, Harsimran Bhatia, Akshay Kumar Saxena, Sadhna B Lal, Kushaljit Singh Sodhi

Abstract read
PubMed Publisher
In one paragraph

Article in Abdominal radiology (New York), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Ultrasound Elastography in Children.Children (Basel, Switzerland) · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Anmol BhatiaDepartment of Radio Diagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh, 160012, India. anmol_bhatia26@yahoo.co.in.ORCID http://orcid.org/0000-0003-4630-5742
Harsimran BhatiaDepartment of Radio Diagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh, 160012, India.
Akshay Kumar SaxenaDepartment of Radio Diagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh, 160012, India.
Sadhna B LalDepartment of Pediatric Gastroenterology, Postgraduate Institute of Medical Education and Research, Sector-12, Chandigarh, 160012, India.
Kushaljit Singh SodhiDepartment of Radio Diagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh, 160012, India.
Post Graduate Institute of Medical Education and Research · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the shear wave elastography (SWE) values of the spleen in healthy children using Elastography Point Quantification (ElastPQ).

methodsIn this IRB approved prospective study, spleen stiffness was measured in 146 healthy children (2-15 years) using ElastPQ. SWE values were recorded in upper pole, mid pole, and lower pole of the spleen in all the children.

resultsThe mean (± SD) SWE values of the spleen in children in ≤ 5 years age group, > 5-10 years age group, and > 10-15 years age group were 5.6 (± 4.2) kPa, 6.5 (± 3.2) kPa, and 5.9 (± 3.6) kPa, respectively. No statistically significant difference was seen in SWE values of the spleen between these three groups (p > 0.5). The mean (± SD) SWE values in ≤ 10 years and > 10 years age group were 6.1 (± 3.6) kPa and 5.9 (± 2.6) kPa, respectively. No statistically significant difference was seen in SWE values of the spleen between these two groups (p > 0.5). There was no significant difference in the SWE values for boys and girls. Statistically significant difference was seen between the mean SWE values in the two groups based on the median splenic length, which was 5.5 (± 3.8) kPa in the group with a length of ≤ 7.6 cm and 6.7 (± 2.8) kPa in the group with a length of > 7.6 cm.

conclusionSWE values of the spleen in healthy children do not correlate with age, and no significant difference is there in the SWE values for boys and girls. There was a statistically significant difference in the SWE values of the spleen while comparing the groups based on the median splenic length.

Indexed as

Elasticity Imaging TechniquesAdolescentChildChild, PreschoolFemaleHumansLiverMaleProspective StudiesSpleenChildrenElastography point quantificationSpleen

Identifiers

PMID35437707
OpenAlexW4224224455

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.