Evidence map›Paper›PMID 35436187›Full record

ArticleIEEE transactions on medical imaging2022

Dynamic Imaging Using Deep Bi-Linear Unsupervised Representation (DEBLUR).

Abdul Haseeb Ahmed, Qing Zou, Prashant Nagpal, Mathews Jacob

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Multi-dynamic deep image prior for cardiac MRI.Magnetic resonance in medicine · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Abdul Haseeb Ahmed
Qing Zou
Prashant Nagpal
Mathews Jacob

Funding

Novel Computational Framework for Free-Breathing & Ungated Dynamic MRIR01EB019961 · NIBIB · UNIVERSITY OF VIRGINIA · PI Mathews Jacob · 2016 to 2026
$4.0M
Model Based Deep Learning Framework for Ultra-High Resolution Multi-Contrast MRIR01AG067078 · NIA · UNIVERSITY OF VIRGINIA · PI JACOB, MATHEWS · 2021 to 2025
$3.4M
University of Iowa - Research 3T MRI Connectome UpgradeS10OD025025 · OD · UNIVERSITY OF IOWA · PI MAGNOTTA, VINCENT A · 2018 to 2018
$1.9M
Fast Multi-dimensional Diffusion MRI with Sparse Sampling and Model-basedDeep Learning ReconstructionR01EB031169 · NIBIB · UNIVERSITY OF VIRGINIA · PI MANI, MERRY · 2021 to 2024
$1.7M
NIA NIH HHS R01 AG067078NIBIB NIH HHS R01 EB019961NIBIB NIH HHS R01 EB031169NIH HHS S10 OD025025
6 · The paper itself

Abstract

Bilinear models such as low-rank and dictionary methods, which decompose dynamic data to spatial and temporal factor matrices are powerful and memory-efficient tools for the recovery of dynamic MRI data. Current bilinear methods rely on sparsity and energy compaction priors on the factor matrices to regularize the recovery. Motivated by deep image prior, we introduce a novel bilinear model, whose factor matrices are generated using convolutional neural networks (CNNs). The CNN parameters, and equivalently the factors, are learned from the undersampled data of the specific subject. Unlike current unrolled deep learning methods that require the storage of all the time frames in the dataset, the proposed approach only requires the storage of the factors or compressed representation; this approach allows the direct use of this scheme to large-scale dynamic applications, including free breathing cardiac MRI considered in this work. To reduce the run time and to improve performance, we initialize the CNN parameters using existing factor methods. We use sparsity regularization of the network parameters to minimize the overfitting of the network to measurement noise. Our experiments on free-breathing and ungated cardiac cine data acquired using a navigated golden-angle gradient-echo radial sequence show the ability of our method to provide reduced spatial blurring as compared to classical bilinear methods as well as a recent unsupervised deep-learning approach.

Indexed as

AlgorithmsImage Processing, Computer-AssistedMagnetic Resonance ImagingNeural Networks, ComputerRespiration

Identifiers

PMID35436187
PMCPMC9744437

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.