ArticleProgress in rehabilitation medicine2022

Accuracy of Heart Rate and Respiratory Rate Measurements Using Two Types of Wearable Devices.

Yusuke Takahashi, Kazuki Okura, Shin Minakata, Motoyuki Watanabe, Kazutoshi Hatakeyama, Satoaki Chida, Kimio Saito, Toshiki Matsunaga, Yoichi Shimada

Abstract read
In one paragraph

Article in Progress in rehabilitation medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Social jet lag and morning blood pressure surge-central nervous system matters?Hypertension research : official journal of the Japanese Society of Hypertension · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yusuke TakahashiDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Kazuki OkuraDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Shin MinakataDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Motoyuki WatanabeDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Kazutoshi HatakeyamaDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Satoaki ChidaDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Kimio SaitoDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Toshiki MatsunagaDepartment of Rehabilitation Medicine, Akita University Hospital, Akita, Japan.
Yoichi ShimadaAkita Prefectural Development and Disability Organization, Akita, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Wearable devices such as fitness trackers have become popular in the healthcare field. Tracking heart rate and respiratory rate, in addition to physical activity, may provide an accurate picture of daily health. We believe that a combination of two types of devices can simultaneously measure and record physical activity, heart rate, and respiratory rate. However, the measurement accuracies of these two types of devices are not clear. This study aimed to determine the measurement accuracies of two wearable devices for heart and respiratory rate measurements. Methods: Ten healthy men performed incremental load tests (ILTs) and constant load tests (CLTs) on a cycle ergometer. The heart and respiratory rates were measured using wrist-worn (Silmee W22, TDK, Japan, Tokyo) and respiratory tracking devices (Spire Stone, Spire Health, San Francisco, CA, USA), respectively. A 12-lead electrocardiograph and the breath-by-breath method were used as external standards for heart and respiratory rates, respectively. Results: Bland-Altman analysis showed that heart rate had a fixed bias at rest and during ILT and CLT and had a proportional bias during CLT. The standard error values of the regression at rest and during CLT were less than 10 bpm for heart rate and less than 5.0 /min for respiratory rate. During ILT, the standard error was greater than 10 bpm for heart rate and approximately 5.0 /min for respiratory rate. Conclusions: The heart and respiratory rate measurements obtained using wearable devices were accurate within the practical margin of error.

Indexed as

accuracyexercise load testheart raterespiratory ratewearable device

Identifiers

PMID35434406
PMCPMC8983874

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.