Evidence map›Paper›PMID 35433976›Full record

ArticleAnnals of translational medicine2022

A randomized controlled trial: evaluation of efficiency and safety of a novel surgical guide in the extraction of deeply impacted supernumerary teeth in the anterior maxilla.

Jiefan Liu, Xiaole Wang, Peifen Shan, Sunqiang Hu, Dengfeng Liu, Jianfeng Ma, Xin Nie

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jiefan LiuDepartment of Oral and Maxillofacial Surgery, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Xiaole WangDepartment of Orthodontics, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Peifen ShanDepartment of Prosthodontics, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Sunqiang HuDepartment of Oral and Maxillofacial Surgery, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Dengfeng LiuDepartment of Oral and Maxillofacial Surgery, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Jianfeng MaDepartment of Prosthodontics, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Xin NieDepartment of Oral and Maxillofacial Surgery, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Wenzhou Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Preoperative X-ray and cone-beam computed tomography (CBCT) are helpful for locating supernumerary teeth, but the images cannot be transferred to the operation. To design a novel surgical guide plate for intraoperative navigation, we transfer the patient's oral CBCT and gypsum model scan data to a computer for analysis. In our study, we evaluate the efficiency and safety of a novel surgical guide plate for the extraction of deeply impacted supernumerary teeth (DIMSNT) in the anterior maxilla. Methods: Forty patients treated at the Department of School & Hospital of Stomatology, Wenzhou Medical University from March 2019 to December 2020 with DIMSNT (type II/III according to Liu Results: All patients completed the surgery successfully. The guides for group I had a good application effect. Group I's operation time (23.35±5.39 min) was shorter than group II (29.60±9.76 min) (P=0.0194). The average pain degree of group I (1.8±1.08) was significantly less than group II (2.82±1.68) (P<0.05). The average swelling score of group I (34) was significantly less than group II (44.7). Patient satisfaction was significantly higher in group I (8.95±1.05) than in group II (7.90±1.51) (P=0.0152). Conclusions: The novel surgical guide assisted with DIMSNT extraction have been effective in improving the quality of the surgery, patient satisfaction, and reduce its difficulty and duration. We can construct a surgical guide plate to guide the incision and osteotomy in DIMSNT surgery through the data analysis of DIMSNT on computer, which has a broad application prospect for clinical use. Trial registration: Chinese Clinical Trial Registry ChiCTR2100054523.

Indexed as

Cone-beam computed tomography (CBCT)minimally invasivesupernumerary teethsurgical guide

Identifiers

PMID35433976
PMCPMC9011240
OpenAlexW4224296412

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.