Evidence map›Paper›PMID 35433006›Full record

ArticleJournal of materials chemistry. C2022

Microfluidic oxygen tolerability screening of nanocarriers for triplet fusion photon upconversion.

Jussi Isokuortti, Iiro Kiiski, Tiina Sikanen, Nikita Durandin, Timo Laaksonen

Abstract read
In one paragraph

Article in Journal of materials chemistry. C, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jussi IsokuorttiFaculty of Engineering and Natural Sciences, Tampere University Tampere Finland jussi.isokuortti@tuni.fi nikita.durandin@tuni.fi.ORCID https://orcid.org/0000-0002-4379-0087
Iiro KiiskiFaculty of Pharmacy, Drug Research Program, University of Helsinki Helsinki Finland.ORCID https://orcid.org/0000-0001-8677-9032
Tiina SikanenFaculty of Pharmacy, Drug Research Program, University of Helsinki Helsinki Finland.ORCID https://orcid.org/0000-0002-0788-1301
Nikita DurandinFaculty of Engineering and Natural Sciences, Tampere University Tampere Finland jussi.isokuortti@tuni.fi nikita.durandin@tuni.fi.ORCID https://orcid.org/0000-0002-5734-7377
Timo LaaksonenFaculty of Engineering and Natural Sciences, Tampere University Tampere Finland jussi.isokuortti@tuni.fi nikita.durandin@tuni.fi.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The full potential of triplet fusion photon upconversion (TF-UC) of providing high-energy photons locally with low-energy excitation is limited in biomedicine and life sciences by its oxygen sensitivity. This hampers the applicability of TF-UC systems in sensors, imaging, optogenetics and drug release. Despite the advances in improving the oxygen tolerability of TF-UC systems, the evaluation of oxygen tolerability is based on comparing the performance at completely deoxygenated (0% oxygen) and ambient (20-21%) conditions, leaving the physiological oxygen levels (0.3-13.5%) neglected. This oversight is not deliberate and is only the result of the lack of simple and predictable methods to obtain and maintain these physiological oxygen levels in an optical setup. Herein, we demonstrate the use of microfluidic chips made of oxygen depleting materials to study the oxygen tolerability of four different micellar nanocarriers made of FDA-approved materials with various oxygen scavenging capabilities by screening their TF-UC performance over physiological oxygen levels. All nanocarriers were capable of efficient TF-UC even in ambient conditions. However, utilizing oxygen scavengers in the oil phase of the nanocarrier improves the oxygen tolerability considerably. For example, at the mean tumour oxygen level (1.4%), nanocarriers made of surfactants and oil phase both capable of oxygen scavenging retained remarkably 80% of their TF-UC emission. This microfluidic concept enables faster, simpler and more realistic evaluation of, not only TF-UC, but any micro or nanoscale oxygen-sensitive system and facilitates their development and implementation in biomedical and life science applications.

Identifiers

PMID35433006
PMCPMC8944590

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.