Evidence map›Paper›PMID 35431226›Full record

ArticleJournal of back and musculoskeletal rehabilitation2022

Core muscle strength can be reliably measured using a novel isokinetic device: An intra-observer study.

Marit L Mulder, Elke Van den Steen, Jan De Neve, Adam Weir

Abstract read
In one paragraph

Article in Journal of back and musculoskeletal rehabilitation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Marit L MulderDepartment of Orthopaedics and Sports Medicine, Erasmus MC University Medical Centre for Groin Injuries, Rotterdam, The Netherlands.
Elke Van den SteenAZ Sint-Jan hospital, Bruges, Belgium.
Jan De NeveAZ Sint-Jan hospital, Bruges, Belgium.
Adam WeirDepartment of Orthopaedics and Sports Medicine, Erasmus MC University Medical Centre for Groin Injuries, Rotterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCore strength is an important aspect of physical fitness. A dynamometer was developed to measure isokinetic core muscle strength in multiple planes of motion. Establishing the reliability is needed before it can be used in practice.

objectiveExamine the intra-observer reliability of a trunk isokinetic dynamometer.

methods31 participants were recruited. Tests were performed twice with an interval of 5-9 days by the same observer. Testing included rotation, flexion/extension and lateral flexion at speeds of 90∘/s and 60∘/s. The main outcome measure was peak torque (PT). The secondary outcomes included peak torque angle (PTA), time to peak torque (TTPT) and compensatory torques (CompTQ). The intra-observer reliability was investigated using intraclass correlation coefficients (ICC).

resultsPeak torque reliability was good to excellent (ICC = 0.70-0.91), whereas the reliability of the PTA (ICC =-0.04-0.56) and TTPT (ICC = 0.01-0.68) were poor to moderate. CompTQ reliability was moderate to good (ICC = 0.20-0.88).

conclusionsThe intra-observer reliability of the isokinetic measurement of core strength peak torque was good. The secondary outcomes peak torque angle and time to peak torque were less reliable and the compensatory torques showed moderate to good reliability. This isokinetic dynamometer could have useful applications in the field of sports medicine and rehabilitation.

Indexed as

Muscle, SkeletalMuscle StrengthHumansMuscle Strength DynamometerReproducibility of ResultsTorqueCore strengthdynamometerisokineticpeak torquesports medicine

Identifiers

PMID35431226
PMCPMC9535570

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.