Evidence map›Paper›PMID 35430808›Full record

ArticleBMC sports science, medicine & rehabilitation2022

Comprehensive validation of a wearable foot sensor system for estimating spatiotemporal gait parameters by simultaneous three-dimensional optical motion analysis.

Kentaro Homan, Keizo Yamamoto, Ken Kadoya, Naoki Ishida, Norimasa Iwasaki

Abstract read
In one paragraph

Article in BMC sports science, medicine & rehabilitation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Assessment of the reproducibility and accuracy of the VisiaGMS Interdisciplinary plastic and reconstructive surgery DGPW · 2023
    Article
  7. FactorsSage open aging
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kentaro HomanDepartment of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan.
Keizo YamamotoSchool of Lifelong Sport, Hokusho University, 23 Bunkyodai, Ebetsu, 069-8511, Japan.
Ken KadoyaDepartment of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan. kadoya@med.hokudai.ac.jp.
Naoki IshidaDepartment of Orthopedic Surgery, Hokuto Medical Corporation Hokuto Hospital, Kisen 7-5 Inada-cho, Obihiro, Hokkaido, Japan.
Norimasa IwasakiDepartment of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUse of a wearable gait analysis system (WGAS) is becoming common when conducting gait analysis studies due to its versatility. At the same time, its versatility raises a concern about its accuracy, because its calculations rely on assumptions embedded in its algorithms. The purpose of the present study was to validate twenty spatiotemporal gait parameters calculated by the WGAS by comparison with simultaneous measurements taken with an optical motion capture system (OMCS).

methodsTen young healthy volunteers wore two inertial sensors of the commercially available WGAS, Physilog®, on their feet and 23 markers for the OMCS on the lower part of the body. The participants performed at least three sets of 10-m walk tests at their self-paced speed in the laboratory equipped with 12 high-speed digital cameras with embedded force plates. To measure repeatability, all participants returned for a second day of testing within two weeks.

resultsTwenty gait parameters calculated by the WGAS had a significant correlation with the ones determined by the OMCS. Bland and Altman analysis showed that the between-device agreement for twenty gait parameters was within clinically acceptable limits. The validity of the gait parameters generated by the WGAS was found to be excellent except for two parameters, swing width and maximal heel clearance. The repeatability of the WGAS was excellent when measured between sessions.

conclusionThe present study showed that spatiotemporal gait parameters estimated by the WGAS were reasonably accurate and repeatable in healthy young adults, providing a scientific basis for applying this system to clinical studies.

Indexed as

Gait analysisThree-dimensional motion analysisValidation studyWearable sensor

Identifiers

PMID35430808
PMCPMC9013462

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked